Abstract: El objetivo principal del estudio es evaluar y obtener los valores de resistencia característica de las uniones dentadas de madera Tornillo (Cedrelinga cateniformis D. Ducke), para su utilización en la fabricación de vigas de madera laminada para uso estructural. Se elaboraron 80 probetas con unión dentada encoladas con MUF (Melamina Úrea Formaldehído), de las cuales 40 probetas fueron ensayadas a flexión estática a 4 puntos de acuerdo con lo indicado por la norma EN 408 y las otras 40 probetas fueron ensayadas a tracción paralela a la fibra siguiendo las pautas indicadas por la norma NBR 7190 y la metodología de ensayo presentada por Mohamad (2011). La resistencia característica a flexión y tracción paralela a la fibra de las uniones dentadas obtenidas fueron de 38.11 MPa y 35.11 MPa respectivamente. La resistencia característica a flexión fue similar a la resistencia mínima a flexión de las uniones dentadas de láminas (38MPa) encontrada en la norma EN 14080, mientras que la resistencia característica a tracción paralela a la fibra logró superar los 29 MPa, valor asignado a la clase resistente más alta de la norma EN 14080. Para cada ensayo efectuado se clasificaron y caracterizaron cada una de las probetas por tipo de falla, con la finalidad de evaluar la calidad del encolado de la unión fabricada. En esta etapa de análisis la mayoría de uniones dentadas produjeron un 100% de rotura por madera (falla tipo 1) y rotura por madera - adhesivo (falla tipo 2), es decir, el encolado funcionó adecuadamente.

The main objective of the study is to evaluate and obtain the values of resistance characteristic of the finger joints of wood Tornillo (Cedrelinga cateniformis D. Ducke), for its use in the manufacture of laminated wooden beams for structural use. They were made 80 specimens with finger joints glued with MUF (Melamine Urea Formaldehyde) were prepared, of which 40 test pieces were tested to static bending at 4 points according to what is indicated by the EN 408 standard and the other 40 specimens were tested with under tension parallel of the fiber following the guidelines indicated by the NBR 7190 standard and the test methodology presented by Mohamad (2011). The characteristic resistance to bending and tensile parallel to the fiber of the finger joints obtained were 38.11 MPa and 35.11 MPa respectively. The characteristic resistance to bending was similar to the minimum bending strength of the finger joints of lamellas (38MPa) found in the EN 14080 standard, while the characteristic resistance to tensile parallel to the fiber exceeded 29 MPa, value assigned to the highest resistant class of the EN 14080 standard. For each test carried out, each of the specimens was classified and characterized by type of failure, in order to evaluate the quality of the bonding of the manufactured joint. In this analysis stage, most of the finger joints produced 100% breakage towood (type 1 failure) and breakage by wood and adhesive (type 2 failure), that is, the gluing worked properly.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Nacional de Ingeniería. Facultad de Ingeniería Civil
Grade or title: Ingeniero Civil
Juror: Vargas Rodríguez, Luis Hugo
Register date: 17-Jun-2021