Buscar en Google Scholar
Título: Evaluación estructural de 3 edificaciones variando la categoría estructural en el departamento de Lima
Otros títulos: Structural Evaluation of 3 Buildings Varying Structural Categories in the Department of Lima
Campo OCDE: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Fecha de publicación: 15-nov-2024
Institución: Universidad Peruana de Ciencias Aplicadas (UPC)
Resumen: El Cinturón de Fuego es responsable del 90% de los terremotos, lo que representa un riesgo significativo para Perú, especialmente en Lima, que ha experimentado un silencio sísmico de 278 años. La autoconstrucción en esta región frecuentemente resulta en viviendas con baja capacidad sísmica. Esta investigación se centra en analizar tres edificaciones que han cambiado su categoría estructural con el objetivo determinar factores iniciales para realizar un cambio de uso. El cual, se realiza mediante un análisis técnico del cambio de uso estructural, se han identificado incrementos significativos en el peso y la resistencia de los edificios al transitar de la categoría C a las categorías B y A. Se establecieron parámetros de incremento de peso del 18.35% y 20.20% para las transiciones de C a B y de C a A, respectivamente, junto con factores de 1.1835 y 1.2020 que facilitan determinar el incremento del peso de la estructura. Mientras para la resistencia en el eje X, los factores de incremento son de 1.2416 para la categoría B y 1.2724 para la categoría A. Asimismo se determina en el eje Y, son de 1.1904 para B y 1.2930 para A. Estos hallazgos subrayan la importancia de considerar estos factores al realizar un cambio en el uso de una estructura.

The Pacific Ring of Fire is responsible for 90% of earthquakes, posing a significant risk to Peru, particularly in Lima, which has experienced a seismic silence of 278 years. Self-construction in this region often results in housing with low seismic capacity. This research focuses on analyzing three buildings that have changed their structural category in order to determine initial factors for a change of use. Through a technical analysis of the structural change of use, significant increases in the weight and resistance of the buildings have been identified when transitioning from category C to categories B and A. Parameters for weight increase of 18.35% and 20.20% were established for the transitions from C to B and from C to A, respectively, along with factors of 1.1835 and 1.2020 to facilitate the determination of the weight increase of the structure.In terms of resistance, the factors of increase for the X-axis are 1.2416 for category B and 1.2724 for category A. Similarly, the factors for the Y-axis are 1.1904 for B and 1.2930 for A. These findings highlight the importance of considering these factors when making a change in the use of a structure.
Enlace al repositorio: http://hdl.handle.net/10757/683047
Disciplina académico-profesional: Ingeniería Civil
Institución que otorga el grado o título: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grado o título: Ingeniero Civil
Jurado: Anza Moreau, Cesar Augusto; Alvarez Miranda, David Humberto
Fecha de registro: 12-dic-2024



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons