Citas bibligráficas
Villafuerte, G., (2016). Evaluación comparativa del comportamiento dinámico por métodos teóricos y experimentales, con vibración forzada, en los bloques 01 y 02 de la I.E. Mixta Nº 50037 de Chimpahuaylla con sistemas estructurales de pórticos de concreto armado, considerando el efecto de la tabiquería y sin considerar ese efecto. [Tesis, Universidad Andina del Cusco]. https://hdl.handle.net/20.500.12557/729
Villafuerte, G., Evaluación comparativa del comportamiento dinámico por métodos teóricos y experimentales, con vibración forzada, en los bloques 01 y 02 de la I.E. Mixta Nº 50037 de Chimpahuaylla con sistemas estructurales de pórticos de concreto armado, considerando el efecto de la tabiquería y sin considerar ese efecto. [Tesis]. : Universidad Andina del Cusco; 2016. https://hdl.handle.net/20.500.12557/729
@misc{sunedu/3042523,
title = "Evaluación comparativa del comportamiento dinámico por métodos teóricos y experimentales, con vibración forzada, en los bloques 01 y 02 de la I.E. Mixta Nº 50037 de Chimpahuaylla con sistemas estructurales de pórticos de concreto armado, considerando el efecto de la tabiquería y sin considerar ese efecto.",
author = "Villafuerte Valencia, Gerardo Rodrigo",
publisher = "Universidad Andina del Cusco",
year = "2016"
}
In this research was evaluated and compared different structural dynamic behaviors and properties of the blocks 01 and 02 of the “I.E. Mixta N°50037” located in Chimpahuaylla, above forced vibrations produced by a compact roller. The dynamic behavior and properties of the buildings were obtained in the next cases: in “real edifications” (experimental cases), through the recollection of acceleration responses with an accelerometer; and in “buildings with structural system of reinforced concrete framework” and in “buildings with structural system of reinforced concrete framework with stiffness modification by the interaction between partition walls and concrete frames” (theoretical cases), through handmade time history analysis and modal superposition and calculation with software. Finally, the research concluded that through the comparison between the theoretical cases with the experimental cases, the buildings don’t present any modification of stiffness by the masonry partition walls, except the “X” direction from the block 01, which presents a mild modification. In consequence, in the conditions of the research, the construction method used in the buildings is effective in terms of isolating the partition walls from the reinforced concrete frames.
IMPORTANTE
La información contenida en este registro es de entera responsabilidad de la universidad, institución o escuela de educación superior que administra el repositorio académico digital donde se encuentra el trabajo de investigación y/o proyecto, los cuales son conducentes a optar títulos profesionales y grados académicos. SUNEDU no se hace responsable por los contenidos accesibles a través del Registro Nacional de Trabajos de Investigación – RENATI.