Chacón Sánchez, Víctor
Valer Mayorga, Alvaro Alonso
Santa Cruz Borda, Jhort Kenvi
2024-03-22T20:24:42Z
2024-03-22T20:24:42Z
2023-12-19
https://hdl.handle.net/20.500.12557/6157
La presente tesis de investigación tiene por finalidad mejorar las propiedades físico-mecánicas del ladrillo industrializado King Kong 18 huecos, optimizando sus propiedades según el clima frio de nuestra región, se analizaron las características físicas (variación dimensional, alabeo, succión, absorción y conductividad térmica) y mecánicas (resistencia a la compresión) de ladrillos de 9cm x 13cm x 24cm, fabricados con arcilla, arena, tierra negra y agua., variando la dosificación de sus componentes con respecto al ladrillo industrializado tradicional de la empresa (Arcilla 30% - Arena 50% - Tierra Negra 20%), modificando sus porcentajes de arcilla y arena correspondientemente, incorporando diferentes porcentajes de arcilla en las dosificaciones planteadas (Dosificación N°1 a N°5). Estas variaciones se realizaron tomando como referencia la composición del ladrillo industrializado tradicional de la empresa y la revisión bibliográfica. La elaboración y producción de las unidades de albañilería fue llevada a cabo en la empresa Ladrillos Muralla S.R.L., empleando los equipos, maquinaria industrial y materiales de mencionada empresa. Las pruebas que se llevaron a cabo en los materiales como granulometría, límites de Atterberg se realizaron de acuerdo a las especificaciones establecidas en las normas técnicas peruanas (NTP 400.012-2013 y NTP 339.129.1998). Los ensayos sometidos a los ladrillos tales como análisis de variación dimensional, alabeo, succión, absorción, resistencia a la compresión se realizaron de acuerdo a las especificaciones de la norma técnica peruana (NTP 399.613 2017 UNIDADES DE ALBANILERIA. En general la NTP.070). Y por último el ensayo de conductividad térmica se realizó de acuerdo a las especificaciones establecidas en la ASTM C177-13. Habiendo sometido a prueba un total de 120 unidades de albañilería. En conclusión. Se comprobó que los resultados más favorables lo presentaron las unidades de albañilería con la dosificación N°5 (+5% de arena), presentando el valor promedio de conductividad térmica menor de 0.3328 W/(m*°K) y la dosificación tradicional presenta el valor promedio mayor de resistencia a la compresión 274.1 kg/cm2 y cumpliendo satisfactoriamente con los demás ensayos según la NTP.070. (es_PE)
The purpose of this research thesis is to enhance the physical and mechanical properties of the industrialized King Kong 18-hole brick, optimizing its features according to the cold climate of our region. The study analyzed the physical (dimensional variation, warping, suction, absorption, and thermal conductivity) and mechanical (compressive strength) characteristics of bricks measuring 9cm x 13cm x 24cm. These were manufactured using clay, sand, black soil, and water, with variations in component proportions compared to the traditional industrialized brick of the company (Clay 30% - Sand 50% - Black Soil 20%). Different percentages of clay were incorporated in the proposed formulations (Dosage No. 1 to No. 5), guided by the composition of the traditional industrialized brick and literature review. The production of masonry units took place at Ladrillos Muralla S.R.L., utilizing the company's equipment, industrial machinery, and materials. Tests on materials such as gradation and Atterberg limits followed the specifications of Peruvian technical standards (NTP 400.012-2013 and NTP 339.129.1998). Tests on bricks, including dimensional variation, warping, suction, absorption, and compressive strength, were conducted according to the Peruvian technical standard (NTP 399.613-2017 MASONRY UNITS. Overall, NTP.070). The thermal conductivity test adhered to ASTM C177-13 specifications, with a total of 120 masonry units subjected to testing. In conclusion. It was found that the most favorable results were presented by the masonry units with dosage No. 5 (+5% sand), presenting the average thermal conductivity value of less than 0.3328 W/(m*°K) and the traditional dosage presents the highest average value of compressive strength was 274.1 kg/cm2 and satisfactorily complying with the other tests according to NTP.070. (en_US)
application/pdf (es_PE)
spa (es_PE)
Universidad Andina del Cusco (es_PE)
info:eu-repo/semantics/openAccess (es_PE)
https://creativecommons.org/licenses/by-nc-nd/4.0/ (es_PE)
Unidades de albañilería (es_PE)
Dosificación (es_PE)
Propiedades físico-mecánicas (es_PE)
Evaluación de la conductividad térmica, propiedades físico-mecánicas del ladrillo King-Kong 18 huecos para diferentes dosificaciones de sus componentes con respecto al ladrillo industrializado del sector Oscollopampa - Cusco 2023. (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Andina del Cusco. Facultad de Ingeniería y Arquitectura (es_PE)
Ingeniería Civil (es_PE)
Ingeniero Civil (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.01.01 (es_PE)
https://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
23807993
https://orcid.org/0000-0001-6891-6902 (es_PE)
73953436
70683267
732016 (es_PE)
Alvarez Monterola, Walter Roberto
Arohuanca Sosa, Rode Luz
Gil Rodríguez, Carmen Cecilia
Aguilar Huerta, Jose Ronald
https://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada asociativa



This item is licensed under a Creative Commons License Creative Commons