Citas bibligráficas
Gutiérrez, E., (2016). Análisis y determinación de agua no facturada (ANF) en el sistema de abastecimiento de agua potable en la sub zona Larapa en la E.P.S. Seda Cusco S.A. [Tesis, Universidad Andina del Cusco]. https://hdl.handle.net/20.500.12557/712
Gutiérrez, E., Análisis y determinación de agua no facturada (ANF) en el sistema de abastecimiento de agua potable en la sub zona Larapa en la E.P.S. Seda Cusco S.A. [Tesis]. : Universidad Andina del Cusco; 2016. https://hdl.handle.net/20.500.12557/712
@misc{renati/957546,
title = "Análisis y determinación de agua no facturada (ANF) en el sistema de abastecimiento de agua potable en la sub zona Larapa en la E.P.S. Seda Cusco S.A.",
author = "Gutiérrez Baca, Erick Felipe",
publisher = "Universidad Andina del Cusco",
year = "2016"
}
This thesis entitled “Analysis and Determination of Unbilled Water (ANF) in the drinking water supply system in the sub area of Larapa in the E.P.S. Sedacusco S.A “. Has the objective of analyzing and determining the percentage of loss of unprocessed water (ANF), which has been a social problem due to the scarcity of this vital service and the active economic problem of sanitation service companies in their desire to reduce the amount of drinking water loss in the sub area Larapa. The research has been carried out in the department of Cusco, Province of Cusco, San Jerónimo District, Larapa Urbanization, in the area “XI“ Vilcanota, sub area “XI-III“ Larapa, so named by the company providing sanitation services . The main objective was to analyze and determine the percentage of Unbilled Water (ANF) in the Potable Water Supply System, through which to determine the current functioning of the drinking water supply system. The methodology used consisted of an inventory of losses of water in relation to operational losses and commercial losses. The collection of necessary data such as: types of piping, meter readings already installed in the field and test meters, location of water leakage points in log boxes, leakage points in ruts and clamps, leakage points in networks Of distribution, sectoralization for the test of watertightness in order to determine the percentage of unbilled Water (ANF), later the analysis of the current situation of the operation of the system of supply of drinking water was realized. Finally, it was determined that the percentage of Unbilled Water (ANF) in the drinking water supply system of the Larapa sub-area is 69% of the total distribution volume in the entire drinking water distribution network in the sub area Larapa.
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons