Bibliographic citations
Espinosa, M., Zavaleta, M. (2023). Evaluación del impacto en el sistema de abastecimiento de agua potable de la zona operacional IV-II con la ampliación de la capacidad de almacenamiento del reservorio Picchu R-4 [Universidad Andina del Cusco]. https://hdl.handle.net/20.500.12557/5871
Espinosa, M., Zavaleta, M. Evaluación del impacto en el sistema de abastecimiento de agua potable de la zona operacional IV-II con la ampliación de la capacidad de almacenamiento del reservorio Picchu R-4 []. PE: Universidad Andina del Cusco; 2023. https://hdl.handle.net/20.500.12557/5871
@misc{renati/957450,
title = "Evaluación del impacto en el sistema de abastecimiento de agua potable de la zona operacional IV-II con la ampliación de la capacidad de almacenamiento del reservorio Picchu R-4",
author = "Zavaleta Luna, Manuel",
publisher = "Universidad Andina del Cusco",
year = "2023"
}
Access to drinking water is an internationally recognized human right, for this reason governments and authorities have a responsibility to guarantee access to drinking water to citizens in order to prevent infectious diseases and the spread of both viruses and bacteria, as well as to ensure the daily development of people. In this sense, drinking water supply systems are essential to guarantee that the population has access to clean and safe water for drinking, cooking, washing. These must meet the parameters established by the National Superintendence of Sanitation Services (SUNASS). The present investigation, using hydraulic modeling, seeks to evaluate the hydraulic efficiency of the drinking water distribution network of the IV-II operation zone, located in the Santiago district, Cusco province and Cusco region, in order to Help reduce current and future deficiencies that may arise in the R-4 Reservoir improvement project. For this, the modeling of the network in its current state was carried out, taking information on consumption by type of connection through the historical data record of the EPS SEDACUSCO S.A. and also using a Portable Flowmeter to collect in-situ data from the Umanchata Line that supplies the area described above. The real behavior was obtained by verifying the different design values and non-revenue water (ANF) was considered, as future data, the increase in the storage volume of the R-4 reservoir was assumed according to the project that EPS SEDACUSCO has for this area, and thus, evaluate its influence on the drinking water supply network and be able to analyze the variation of the endowment parameters, continuity of the drinking water service, pressure and the coefficient of maximum hourly flow.
This item is licensed under a Creative Commons License