Título: Influencia del estabilizador z y el cemento portland tipo IP en las propiedades fisicomecanicas del suelo de subrasante de la prolongación Jose Carlos Mariategui - Alto Qosqo - distrito de San Sebastian- Cusco - 2022.
Asesor(es): Román Villegas, Eigner
Campo OCDE: https://purl.org/pe-repo/ocde/ford#2.01.01
Fecha de publicación: 28-sep-2023
Institución: Universidad Andina del Cusco
Resumen: La presente investigación “Influencia del Estabilizador z y el Cemento Portland tipo IP en las propiedades fisicomecanicas del suelo de subrasante de la prolongación José Carlos Mariátegui - Alto Qosqo - Distrito de San Sebastián- Cusco - 2022.” tiene el objetivo principal de evaluar la influencia del Estabilizador Z (1%, 2% y 4%) y el Cemento portland tipo IP (4%) en las propiedades fisicomecanicas del suelo de la subrasante de la prolongación José Carlos Mariátegui. El enfoque de la presente investigación es cuantitativo, el nivel o alcance es de nivel descriptivo – explicativo, y en cuanto a su diseño es una investigación experimental. Se han realizado ensayos estándar de Granulometría y Limites de consistencia para la clasificación de suelos, y ensayos especiales como Proctor modificado y Capacidad de soporte CBR para la resistencia a la compresión, estos ensayos se realizaron en el laboratorio de la Universidad Andina del Cusco al suelo natural así como al suelo con la adición de Cemento portland tipo IP en un 4% y Estabilizador Z en 1%, 2% y 4% respectivamente, para luego presentar los resultados obtenidos mediante tablas y figuras, a partir de las cuales se evaluaran las variaciones en las características físico mecánicas del suelo para subrasante. A partir del análisis e interpretación de nuestros resultados se concluye que los valores del índice de Plasticidad del suelo natural es de 7.67% y con adición de Cemento y Estabilizador Z obtenemos los valores de 7.93%, 8.61%, 9.10% y 5.26% lo cual nos indica que existe una disminución del índice de plasticidad, las pruebas del ensayo de compactación utilizando energía modificada del suelo natural nos dan un contenido de humedad óptimo de 15.20%, con la adición de 4% Cemento 15.90% y para la adición del Cemento y Estabilizador Z los valores de 14.60%, 14.50% y 14%, este último obtenido con la adición de 4% Cemento y 4% Estabilizador Z, escogiendo el contenido óptimo de humedad del 14% ya que es el menor valor obtenido el cual posee una densidad máxima seca de 1.78 gr/cm3, el índice de capacidad de soporte CBR al 95% de la densidad máxima seca del suelo natural es de 10.07% mientras que con la adición de Cemento y Estabilizador Z se obtiene valores de 63.20%, 56.79%, 67.80% y 99.95% siendo este último nuestro mejor CBR para una adición de 4% de Cemento y 4% de Estabilizador Z .

The present investigation "Influence of the Stabilizer z and the Portland Cement type IP on the physicomechanical properties of the subgrade soil of the extension José Carlos Mariátegui - Alto Qosqo - District of San Sebastián-Cusco - 2022." has the main objective of evaluating the influence of Stabilizer Z (1%, 2% and 4%) and Portland Cement type IP (4%) on the physicomechanical properties of the soil of the subgrade of the José Carlos Mariátegui extension. The approach of the present investigation is quantitative, the level or scope is descriptive - explanatory level, and in terms of its design it is an experimental investigation. Standard granulometry and consistency limits tests have been carried out for the classification of soils, and special tests such as modified Proctor for the degree of compaction and CBR support capacity for compressive strength, these tests were carried out in the laboratory of the University Andina del Cusco to the natural soil as well as to the soil with the addition of Portland Cement type IP in 4% and Stabilizer Z in 1%, 2% and 4% respectively, to then present the results obtained through tables and figures, from which will evaluate the variations in the physical-mechanical characteristics of the soil for subgrade. From the analysis and interpretation of our results, it is concluded that the values of the plasticity index of the natural soil is 7.67% and with the addition of Cement and Z Stabilizer we obtain the values of 7.93%, 8.61%, 9.10% and 5.26%, which indicates that there is a decrease in the plasticity index, the tests of the compaction test using modified energy of the natural soil give us an optimum moisture content of 15.20%, with the addition of 4% Cement 15.90% and for the addition of Cement and Stabilizer Z the values of 14.60%, 14.50% and 14%, the latter obtained with the addition of 4% Cement and 4% Stabilizer Z, choosing the optimal moisture content of 14% since it is the lowest value obtained which has a maximum dry density of 1.78 gr/cm3, the CBR support capacity index at 95% of the maximum dry density of natural soil is 10.07% while with the addition of Cement and Z Stabilizer values of 63.20%, 56.79% are obtained, 67.80% and 99.95%, the latter being our best CBR for an addition of 4% Cement and 4% Z Stabilizer.
Disciplina académico-profesional: Ingeniería Civil
Institución que otorga el grado o título: Universidad Andina del Cusco. Facultad de Ingeniería y Arquitectura
Grado o título: Ingeniero Civil