Look-up in Google Scholar
Full metadata record
Montesinos Cervantes, José Alberto
Mamani Soncco, Randolf
2023-05-17T19:28:25Z
2023-05-17T19:28:25Z
2022-12-28
https://hdl.handle.net/20.500.12557/5443
El presente trabajo de investigación tuvo como objetivo, realizar la comparación del método de la prueba de penetración estándar (SPT) y Corte Directo; para fines de cimentaciones superficiales en edificaciones del APV Jilayhua del Distrito de Yanaoca Provincia de Canas del Departamento De Cusco, determinado el Angulo de fricción y la capacidad portante del suelo. Esto debido a que las obras existentes carecen de estudio previo de suelo, además de incumplir con la norma técnica de edificación (E.050 suelos y cimentaciones), RNE,2018. El principal aporte de la presente investigación es dar a conocer a la población la importancia de hacer un estudio de suelos adecuado, como parte significativa en la construcción de una vivienda. Para lo cual la metodología empleada en esta investigación tuvo un enfoque cuantitativo, con una tipología descriptiva, un nivel aplicativo, un diseño metodológico y un método hipotético deductivo. Se realizaron análisis a partir de 09 ensayos de penetración estándar (SPT), conteo de numero golpes y 09 puntos de corte directo a partir de excavaciones de calicatas para extraer muestras inalteradas. Todos los ensayos fueron realizados en el laboratorio de suelos y concreto de la universidad andina del cusco, donde se realizó el procesamiento de datos y comparación de la capacidad admisible de los suelos obtenidos. Los resultados alcanzados de los ensayos fueron: el ángulo de fricción varía entre 32.8° - 26.5° por lo que se dice que el diseño de cimentaciones superficiales de los suelos de la Asociación Pro Vivienda Jilayhua es adecuado para la construcción, el perfil de los suelos es heterogéneo y se determinó que el suelo es de arena limosa con grava y arena limosa. La permeabilidad del suelo es de 0.01 cm/seg considerándose como buena, la capacidad admisible de los suelos realizada con SPT es de 0.8202 cm y la capacidad realizada con corte directo es de 0.7867 cm. Y por último no existe la probabilidad de ocurrencia del fenómeno de asentamiento ya que no se encontró arcilla y el suelo no presenta nivel freático. (es_PE)
The objective of this research work was to compare the standard penetration test (SPT) and Direct Cut method; For the purposes of superficial foundations in buildings of the APV Jilayhua of the District of Yanaoca, Province of Canas, Department of Cusco, determined the friction angle and the bearing capacity of the soil. This is due to the fact that the existing works lack a prior soil study, in addition to failing to comply with the technical building standard (E.050 soils and foundations), RNE, 2018. The main contribution of this research is to make the population aware of the importance of carrying out an adequate soil study, as a significant part of the construction of a house. Analyzes were carried out from 09 standard penetration tests (SPT), count of number of blows and 09 direct cut points from pits excavations to extract undisturbed samples. All the tests were carried out in the soil and concrete laboratory of the Andean University of Cusco, where the data processing and comparison of the admissible capacity of the soils obtained was carried out. The results obtained from the tests were: the friction angle varies between 32.8 ° - 26.5 °, which is why it is said that the design of superficial foundations of the soils of the Jilayhua Pro Housing Association is suitable for construction, the profile of the soils It is heterogeneous and it was determined that the soil is silty sand with gravel and silty sand. The permeability of the soil is 0.01 cm / sec, considered as good, the admissible capacity of the soils made with SPT is 0.8202 cm and the capacity made with direct cutting is 0.7867 cm. And finally, there is no probability of occurrence of the settlement phenomenon since no clay was found and the soil does not present a water table. (en_US)
application/pdf (es_PE)
spa (es_PE)
Universidad Andina del Cusco (es_PE)
info:eu-repo/semantics/openAccess (es_PE)
https://creativecommons.org/licenses/by-nc-nd/4.0/ (es_PE)
Capacidad portante (es_PE)
Ensayo de penetración estándar (es_PE)
Corte directo (es_PE)
Comparación del método de la prueba estándar de penetración (SPT) y corte directo para fines de cimentación en edificaciones en el APV Jilayhua del distrito de Yanaoca, provincia de Canas, departamento Cusco (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Andina del Cusco. Facultad de Ingeniería y Arquitectura (es_PE)
Ingeniería Civil (es_PE)
Ingeniero Civil (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.01.01 (es_PE)
https://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
25001820
https://orcid.org/0000-0002-3256-7664 (es_PE)
45984959
732016 (es_PE)
Gutierrez Vallejo, Heber Darwin
Cabezas Mancilla, José Humberto
Arbulú Jurado, Cesar Edilberto
Ascue Escalante, Kildare Jussety
https://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada asociativa



This item is licensed under a Creative Commons License Creative Commons