Bibliographic citations
Aragon, L., (2022). Calidad del diseño de prótesis parcial removible en modelos de estudio inferior con clase I de Kennedy realizados por cirujanos dentistas, Cusco 2022 [Universidad Andina del Cusco]. https://hdl.handle.net/20.500.12557/5300
Aragon, L., Calidad del diseño de prótesis parcial removible en modelos de estudio inferior con clase I de Kennedy realizados por cirujanos dentistas, Cusco 2022 []. PE: Universidad Andina del Cusco; 2022. https://hdl.handle.net/20.500.12557/5300
@misc{renati/954341,
title = "Calidad del diseño de prótesis parcial removible en modelos de estudio inferior con clase I de Kennedy realizados por cirujanos dentistas, Cusco 2022",
author = "Aragon Mendoza, Lizbet",
publisher = "Universidad Andina del Cusco",
year = "2022"
}
Objective: The present research work aimed to analyze the quality of the design of the partial prosthesis in lower study models class I Kennedy performed by dental surgeons in the district of Cusco, 2022. Material and methods: The present research work has a quantitative approach, descriptive scope, basic research of prospective, cross-sectional, observational and field type, the population was constituted by dental surgeons who work in offices, centers and clinics registered in RENIPRES, the sample was constituted by 263 dental surgeons the type of sampling was non-probabilistic, the research technique was observational, the instrument that was used was the data collection sheet where the design quality of the lower Kennedy class I partial prosthesis was recorded, which was registered as deficient, regular and adequate according to the design of the components of the removable partial prosthesis in correct and incorrect using a technical sheet; Descriptive statistics of the study variables were performed using frequencies and percentages. Results: The design quality of removable partial prosthesis was poor (44.9%), fair (31.9%), adequate (23.2%). According to its components, the design quality of the occlusal supports was incorrect (55.9%), of the retainers incorrect (61.2%), the minor connectors were incorrect (57.8%), the major connectors were incorrect (64.3%), of the retentions for acrylic bases and extension of the bases of the prostheses was incorrect (63.5%). Conclusions: The design quality of removable partial prosthesis was deficient in dental surgeons in the city of Cusco, and the design quality of the components was incorrect in its highest percentage.
This item is licensed under a Creative Commons License