Citas bibligráficas
Esta es una referencia generada automáticamente. Modifíquela de ser necesario
Portella, J., Vásquez, E. (2022). Evaluación del tiempo de exposición de una resina bulk-fill en preparaciones profundas [Universidad Peruana Cayetano Heredia]. https://hdl.handle.net/20.500.12866/11444
Portella, J., Vásquez, E. Evaluación del tiempo de exposición de una resina bulk-fill en preparaciones profundas []. PE: Universidad Peruana Cayetano Heredia; 2022. https://hdl.handle.net/20.500.12866/11444
@misc{renati/910198,
title = "Evaluación del tiempo de exposición de una resina bulk-fill en preparaciones profundas",
author = "Vásquez Castro, Eva María",
publisher = "Universidad Peruana Cayetano Heredia",
year = "2022"
}
Título: Evaluación del tiempo de exposición de una resina bulk-fill en preparaciones profundas
Otros títulos: Evaluation of the exposure time of a bulk-fill resin in deep preparations
Asesor(es): Delgado Cotrina, Leyla Antoinette
Palabras clave: Microdureza; Tiempo; Resina Compuesta; Polimeriza
Campo OCDE: http://purl.org/pe-repo/ocde/ford#3.02.14
Fecha de publicación: 2022
Institución: Universidad Peruana Cayetano Heredia
Resumen: Antecedentes: Las resinas compuestas tipo Bulk-Fill se han desarrollado a lo largo de los años, y son usadas con mayor frecuencia en piezas posteriores con preparaciones más extensas y profundas. Este material muestra una menor contracción de polimerización. Uno de los beneficios más resaltantes es que, esta podría ser utilizada en incrementos de 4 a 5 mm, disminuyendo así el tiempo de trabajo clínico. Objetivos: Determinar el tiempo de fotoactivación necesario para polimerizar una resina Bulk-Fill ubicada en zonas profundas. Materiales y Métodos: En el presente estudio experimental in vitro, se confeccionaron especímenes de resina compuesta Filtek One Bulk-Fill (3M ESPE, St. Paul, EE.UU.) de 5x5x5 mm color A2 fotoactivado a una distancia de 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s y 3 mm/40 s (n=5). La microdureza superficial se registró en la superficie y en la base de cada espécimen. Resultados: El mayor valor de microdureza se registró en el grupo BF 0 mm/20 s y BF 3 mm/40 s (p<0.05), seguido por los grupos BF 3 mm/20 s y BF 3 mm/30 s (p>0.05). Los menores valores de microdureza se encontraron en los grupos BF 0 mm/10 s y BF 3 mm/10 s. Conclusión: Se requiere de 40 s de fotoactivación para polimerizar una resina Bulk-Fill ubicada en zonas profundas, cuando la lámpara está a una distancia de 3 mm de la superficie de la resina.
Background: Bulk-Fill type composite resins have been developed over the years, and are most often used in posterior parts with more extensive and deeper preparations. This material shows less polymerization shrinkage. One of the most outstanding benefits is that it could be used in increments of 4 to 5 mm, thus decreasing the clinical working time. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Materials and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk-Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.
Background: Bulk-Fill type composite resins have been developed over the years, and are most often used in posterior parts with more extensive and deeper preparations. This material shows less polymerization shrinkage. One of the most outstanding benefits is that it could be used in increments of 4 to 5 mm, thus decreasing the clinical working time. Objectives: To determine the photoactivation time necessary to polymerize a Bulk-Fill resin located in deep areas. Materials and Methods: In the present experimental in vitro study, specimens of Filtek One Bulk-Fill composite resin (3M ESPE, St. Paul, USA) of 5x5x5 mm color A2 photoactivated at a distance of 0 mm/10 s, 0 mm/20 s, 3 mm/10 s, 3 mm/20 s, 3 mm/30 s and 3 mm/40 s (n=5) were fabricated. Surface microhardness was recorded on the surface and at the base of each specimen. Results: The highest microhardness value was recorded in group BF 0 mm/20 s and BF 3 mm/40 s (p<0.05), followed by groups BF 3 mm/20 s and BF 3 mm/30 s (p>0.05). The lowest microhardness values were found in the BF 0 mm/10 s and BF 3 mm/10 s groups. Conclusion: It takes 40 s of photoactivation to polymerize a Bulk-Fill resin located in deep areas, when the lamp is 3 mm away from the resin surface.
Enlace al repositorio: https://hdl.handle.net/20.500.12866/11444
Disciplina académico-profesional: Estomatología
Institución que otorga el grado o título: Universidad Peruana Cayetano Heredia. Facultad de Estomatología Roberto Beltrán Neira
Grado o título: Cirujano Dentista
Jurado: Mas López, Janett; Casas Chávez, Elizabeth Rosario; Tay Chu Jon, Lidia Yileng
Fecha de registro: 14-mar-2022
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons