Look-up in Google Scholar
Title: Remoción de materia orgánica y coliformes termotolerantes de las aguas residuales con microorganismos nativos aislados de la Planta de Tratamiento Covicorti
Advisor(s): Llenque Diaz, Luis Alberto
Issue Date: 2016
Institution: Universidad Nacional de Trujillo
Abstract: RESUMEN Se evaluó la remoción de la materia orgánica y coliformes termotolerantes de aguas residuales con microorganismos aislados de la Planta de Tratamiento Covicorti SEDALIB S.A. a partir de muestras de lodo de la Planta, se hizo el aislamiento y selección de los cultivos nativos, e implementó 06 biorreactores de tanque agitado con 2,6 L de agua residual, 3 fueron inoculados con 0,1 L de bacterias; uno con B. licheniformis BL-05, otro con Streptomyces sp. S-03, el tercero con ambas bacterias, y a los otros 3 se les agregó 0,1 L de agua destilada estéril e incubados a temperatura ambiente ( 27 ±1 ºC ). Desde el día 0 y cada 5 días hasta el día 15, se determinó la materia orgánica mediante la Demanda Bioquímica de Oxígeno y coliformes termotolerantes mediante NMP/100ml. Se evidenció que B. licheniformis BL-05 removió la materia orgánica en un 74,77%; mientras que los coliformes termotolerantes fueron removidos en un 99,69%. Streptomyces sp. SP-03 removió la materia orgánica y coliformes termotolerantes en un 72,09% y 100,00% respectivamente. El tratamiento con el consorcio removió la materia orgánica y coliformes termotolerantes en un 83,64% y 100% respectivamente. Por lo que se concluye que el tratamiento de las aguas residuales con las bacterias en consorcio permitió la mayor remoción de la materia orgánica y coliformes termotolerantes.
Note: ABSTRACT It was evaluated the organic matter removal and thermotolerant coliforms from sewage water with microorganisms isolated from residual water Treatment Plant Covicorti SEDALIB S.A. using samples plant sludge, isolation was done and selection of native crops and it was implemented six bioreactors of stirred tank with 2.6 L of residual wáter, three of them were inoculated with 0,1 L bacterias; one of them with B. licheniformis BL – 05, another with Streptomyces sp. S-03, and the third one with both bacteria, and for the rest were added 0,1 L distilled wáter and incubate at room temperatura (27 ±1 °C). From day zero and every five days until day 15, organic matter was determined by Biochemical Oxygen Demand and thermotolerant coliforms through NMP/100ml. It was found that B. licheniformis BL-05 removed the inorganic matter in a 74,77 %; while thermotolerant coliforms were removed in a 99,69 %. Streptomyces sp. SP-03 removed the organic matter and thermotolerant coliforms in a 72,09 % and 100,00 % respectively. The treatment with the consortium removed organic matter and coliform thermotolerant in a 83,64 % and 100 % respectively. In conclusion, the treatment of wastewater with bacteria in consortium allowed the greater removal of organic matter and thermotolerant coliforms.
Discipline: Maestría en Ciencias mención Biotecnología Agroindustrial y Ambiental
Grade or title grantor: Universidad Nacional de Trujillo.Escuela de Posgrado
Grade or title: Maestra en Ciencias
Register date: 31-Jan-2020



This item is licensed under a Creative Commons License Creative Commons