Bibliographic citations
This is an automatically generated citacion. Modify it if you see fit
Veneros, M., (2022). Análisis Fisicoquímico de gasa fraccionada estéril grande de un laboratorio nacional, 2022. [Universidad Nacional de Trujillo]. https://hdl.handle.net/20.500.14414/19712
Veneros, M., Análisis Fisicoquímico de gasa fraccionada estéril grande de un laboratorio nacional, 2022. []. PE: Universidad Nacional de Trujillo; 2022. https://hdl.handle.net/20.500.14414/19712
@misc{renati/879599,
title = "Análisis Fisicoquímico de gasa fraccionada estéril grande de un laboratorio nacional, 2022.",
author = "Veneros Heros, Mariluz",
publisher = "Universidad Nacional de Trujillo",
year = "2022"
}
Full metadata record
Curo Vallejos, Yuri Freddy
Veneros Heros, Mariluz
2023-11-22T17:00:50Z
2023-11-22T17:00:50Z
2022
https://hdl.handle.net/20.500.14414/19712
El objetivo del informe de prácticas pre-profesionales realizadas en un laboratorio nacional fue evaluar los parámetros fisicoquímicos de gasas fraccionadas estériles grandes, con una muestra de 12 unidades con lote 202011, siendo gasas tipo VI. Se realizaron los siguientes análisis fisicoquímicos: gramaje, conteo de hilos de urdimbre y trama en 2,54 cm, largo y ancho, absorbencia, rayón, residuo incinerado, residuo seco, ácido y álcali, dextrinas, materia grasa y colorantes solubles en alcohol, los cuales son establecidos por la Norma Técnica Peruana, obteniendo resultados conformes en cada prueba fisicoquímica realizada. Finalmente se concluye que la gasa fraccionada estéril grande extendida 25cm x 42cm cumple con las especificaciones establecidas por la Norma Técnica Peruana
ABSTRACT
This pre-professional practice report was carried out in a national laboratory, with the objective of evaluating the physicochemical parameters of large sterile fractionated gauze, with a sample of 12 units with lot 202011, being type VI gauze. The following physicochemical analyzes were performed: grammage, number of warp and weft threads in 2.54 cm, length and width, absorbency, rayon, burnt residue, dry residue, acid and alkali, dextrins, fat and alcohol-soluble dyes, which are established by the Peruvian Technical Standard, obtaining compliant results in each physicochemical test performed. Finally, it is concluded that the large extended sterile fractionated gauze 25cm x 42cm complies with the specifications established by the Peruvian Technical Standard.
application/pdf
spa
Universidad Nacional de Trujillo
info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc/4.0/
Universidad Nacional de Trujillo
Repositorio Institucional UNITRU
Análisis fisicoquímico
Esterilización de materiales
Análisis Fisicoquímico de gasa fraccionada estéril grande de un laboratorio nacional, 2022.
info:eu-repo/semantics/bachelorThesis
Universidad Nacional de Trujillo. Facultad de Farmacia y Bioquímica
Farmacia
Químico Farmacéutico
PE
https://purl.org/pe-repo/ocde/ford#3.01.05
http://purl.org/pe-repo/renati/level#tituloProfesional
16423089
https://orcid.org/0000-0002-9734-5173
70275891
917046
Gutiérrez Mendoza, Danny Daniel
Curo Vallejos, Yuri Freddy
Polo Bardales, José Luis
http://purl.org/pe-repo/renati/type#tesis
Pública
info:eu-repo/semantics/publishedVersion
This item is licensed under a Creative Commons License