Citas bibligráficas
Condori, K., Benavente, J. (2020). Diseño del sistema de agua potable y saneamiento en el caserío de Shoglia, La Libertad, 2019. [Tesis, Universidad Privada de Trujillo]. http://repositorio.uprit.edu.pe/handle/UPRIT/245
Condori, K., Benavente, J. Diseño del sistema de agua potable y saneamiento en el caserío de Shoglia, La Libertad, 2019. [Tesis]. : Universidad Privada de Trujillo; 2020. http://repositorio.uprit.edu.pe/handle/UPRIT/245
@misc{renati/7820,
title = "Diseño del sistema de agua potable y saneamiento en el caserío de Shoglia, La Libertad, 2019.",
author = "Benavente Farfán, José Rolando",
publisher = "Universidad Privada de Trujillo",
year = "2020"
}
In the design of the system of drinking water and sanitation in the hamlet of Shoglia, the freedom, the calculations and technical proposal were made to favor the needs of the residents through the training and operation of the system. Developed in a manner consistent with a methodology based on field work, cabinet work, the recommendations of the National Building Regulation with its standards OS 010, OS 050, IS 010 and IS 020, and the Guide to Technical Options for Supply of Water and Sanitation for Rural Areas of the Ministry of Housing, Sanitation and Construction, in that sense the components of the drinking water system and basic sanitation components of the project in question have been designed, all based on an interview, to the community members , authorities and on-site verification, and data processing in cabinet. The whole process indicated, led to obtaining satisfactory results of the investigation, as well as in relation to the design of 01 slope type pickup, conduction line of 4, 086.34 linear meters, 31 type 06 pressure-breaking chambers, a type 07 Chamber, a 12 m3 reservoir, distribution network with 3,734.35 linear meters of SAP PVC pipe and 47 household connections, corresponding to the drinking water system, in turn, the design of the basic sanitation components such as the 600-liter. The Biodigester was obtained, sludge record box with a 0.6 meter pitch, a length of 0.6 meters and a height of 0.30 meters, a percolation pit. As design was also taken into account in question the pressure losses and optimized pressures to avoid collapses of the system installation, using the appropriate diameter to meet the design and demand.
Fichero | Tamaño | Formato | |
---|---|---|---|
CONDORI FLORES y BENAVENTE FARFAN.pdf Acceso restringido | 18.98 MB | Adobe PDF | Visualizar/Abrir Solicita una copia |
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons