Bibliographic citations
This is an automatically generated citacion. Modify it if you see fit
Saavedra, A., (2018). Evaluación del rendimiento de la bomba de ariete hidráulico multi-impulsor de Breur [Tesis, Universidad Nacional de Ingeniería]. http://hdl.handle.net/20.500.14076/15708
Saavedra, A., Evaluación del rendimiento de la bomba de ariete hidráulico multi-impulsor de Breur [Tesis]. : Universidad Nacional de Ingeniería; 2018. http://hdl.handle.net/20.500.14076/15708
@misc{renati/709448,
title = "Evaluación del rendimiento de la bomba de ariete hidráulico multi-impulsor de Breur",
author = "Saavedra Torres, Alberto",
publisher = "Universidad Nacional de Ingeniería",
year = "2018"
}
Title: Evaluación del rendimiento de la bomba de ariete hidráulico multi-impulsor de Breur
Authors(s): Saavedra Torres, Alberto
Advisor(s): Salazar Gavelán, Roger Edmundo
Keywords: Ariete hidráulico; Bomba de ariete de Breur
Issue Date: 2018
Institution: Universidad Nacional de Ingeniería
Abstract: El presente trabajo de investigación tiene como objetivo principal evaluar el rendimiento de la bomba de ariete de breur con materiales de fácil obtención en el mercado peruano.
Para realizar el estudio se empleó un sistema piloto con condiciones ideales para un mejor desarrollo de las pruebas hidráulicas. La principal variable de estudio fue la cantidad de válvulas de impulsión, se tomó en cuenta 1, 2 y 3 de estas. Además, también se emplearon distintas longitudes de tubería de alimentación las cuales fueron de 4.00, 5.00 y 6.00 metros; y finalmente, se tuvo en cuenta tres distintos tamaños de la cámara de presión (manguera) 0.50, 1.00 y 1.50 metros de largo.
En cada una de las pruebas de bombeo realizadas fueron medidos los valores de presión de salida, cantidad de agua bombeada y cantidad de agua de alimentación; con lo cual luego con una ayuda de hoja de cálculo se determinó los valores de rendimiento en cada una de las configuraciones realizadas a la bomba.
Como resultado se obtuvo que la eficiencia aumentaba a medida que se adicionaban válvulas de impulsión. Mientras que la longitud de la tubería de alimentación y el tamaño de la cámara de presión no hubo una mejora significativa.
Sin embargo, el aumento de la longitud de la tubería de alimentación repercutía de manera directa en el caudal de rendimiento máximo, la altura de máximo rendimiento y la altura máxima de bombeo, obtenido los mayores valores para una longitud de 6.00 metros.
Por otro lado, la longitud de la cámara de presión no represento un cambio significativo en ninguna característica medida ni calculada durante la experimentación.
La eficiencia máxima obtenida fue de 66.40% para un configuración de bomba de ariete con 3 válvulas de impulsión, 4.00 metros de tubería de alimentación y 0.50 metros de cámara de presión. Con la cual se tiene como caudal de máximo rendimiento 1028.80 L/día, altura de máximo rendimiento de 12.77 metros y altura máxima de bombeo de 20.52 metros.
The main objective of this research work is to evaluate the performance of the breur’s ram pump build with materials easily obtained in the Peruvian market. To carry out the study, a pilot system was used with ideal conditions for a better development of hydraulic tests. The main variable of study was the number of impulsion valves, 1, 2 and 3 of these were taken into account. In addition, different lengths of feed pipe were also used which were 4.00, 5.00 and 6.00 meters; and finally, three different sizes of the pressure chamber (hose) 0.50, 1.00 and 1.50 meters long were taken into account. In each of the pumping tests carried out, the values of outlet press ure, amount of water pumped and amount of feed water were measured; with which then with a spreadsheet help the performance values were determined in each of the configurations made to the pump. As a result, it was found that the efficiency increased as im pulsion valves were added. W hile the length of the feed pipe and the size of the pressure chamber was not significantly improved. However, the increase in the length of the feed pipe had a direct impact on the maximum performance flow, the maximum performance height and the maximum pumping height, obtaining the highest values for a length of 6.00 meters. On the other hand, the length of the pressure chamber did not represent a significant change in any feature measured or calculated during the experiment. The maximum efficiency obtained was 66.40% for a ram pump configuration with 3 impulsion valves, 4.00 meters of supply pipe and 0.50 meters of pressure chamber. W ith which it has like discharge of maximum performance 1028.80 L / day, height of maxim um performance of 12.77 meters and maximum height of pumping of 20.52 meters.
The main objective of this research work is to evaluate the performance of the breur’s ram pump build with materials easily obtained in the Peruvian market. To carry out the study, a pilot system was used with ideal conditions for a better development of hydraulic tests. The main variable of study was the number of impulsion valves, 1, 2 and 3 of these were taken into account. In addition, different lengths of feed pipe were also used which were 4.00, 5.00 and 6.00 meters; and finally, three different sizes of the pressure chamber (hose) 0.50, 1.00 and 1.50 meters long were taken into account. In each of the pumping tests carried out, the values of outlet press ure, amount of water pumped and amount of feed water were measured; with which then with a spreadsheet help the performance values were determined in each of the configurations made to the pump. As a result, it was found that the efficiency increased as im pulsion valves were added. W hile the length of the feed pipe and the size of the pressure chamber was not significantly improved. However, the increase in the length of the feed pipe had a direct impact on the maximum performance flow, the maximum performance height and the maximum pumping height, obtaining the highest values for a length of 6.00 meters. On the other hand, the length of the pressure chamber did not represent a significant change in any feature measured or calculated during the experiment. The maximum efficiency obtained was 66.40% for a ram pump configuration with 3 impulsion valves, 4.00 meters of supply pipe and 0.50 meters of pressure chamber. W ith which it has like discharge of maximum performance 1028.80 L / day, height of maxim um performance of 12.77 meters and maximum height of pumping of 20.52 meters.
Link to repository: http://hdl.handle.net/20.500.14076/15708
Discipline: Ingeniería Sanitaria