Title: Dise?o de un prototipo electr?nico para detecci?n temprana contra la neumon?a en infantes
Advisor(s): Huaman? Navarrete, Pedro Freddy
OCDE field: https://purl.org/pe-repo/ocde/ford#2.02.00
Issue Date: 2015
Institution: Universidad Ricardo Palma - URP
Abstract: La neumon?a es la principal causa de muerte en ni?os menores de 5 a?os en el mundo. Se calculan m?s muertes por neumon?a que por VIH, malaria y sarampi?n. Considerando la alta tasa de mortandad infantil por neumon?a; el objetivo principal de este proyecto de tesis, fue dise?ar e implementar un prototipo electr?nico para detecci?n temprana contra la neumon?a en infantes. Para este prop?sito, se us? un sensor de temperatura, el LM35, el cual se adapt? a un electrodo m?dico, de esta manera fue adherido al cuerpo del paciente, adem?s se us? un sensor magn?tico adaptado a una banda el?stica, la cual se coloc? alrededor del t?rax del paciente. Estos sensores midieron la temperatura corporal en ?C y el n?mero de respiraciones por minuto (RPM), respectivamente. Ambas mediciones se acondicionaron, usando el amplificador operacional LM358N y se procesaron usando un Microcontrolador PIC16F877A. Los datos procesados pasaron a una PC mediante una interface de comunicaci?n USB. Previamente en la PC se carg? una aplicaci?n inform?tica escrita y desarrollada en Visual Basic, la cual cont? con una interface gr?fica, donde se visualiz? el resultado de la prueba. Las pruebas se hicieron con siete ni?os de diferentes edades, de los cuales mencionaremos solo a tres. La cuarta prueba se realiz? con un ni?o de 2 a?os de edad, obteniendo como resultado una temperatura corporal de 39?C, 37 RPM y como diagn?stico, la temperatura corporal es excesiva y pr?xima a taquipnea. La quinta prueba se realiz? con una ni?a de cuatro a?os de edad, obteniendo como resultado una temperatura corporal de 39?C, 31 RPM y como diagn?stico, la temperatura corporal es excesiva y pr?xima a taquipnea. La s?ptima prueba se realiz? en una ni?a de 1 a?o de edad, obteniendo como resultado una temperatura corporal de 39?C, 34 RPM y como diagn?stico, la temperatura corporal es excesiva y pr?xima a taquipnea, siendo estas las condiciones necesarias para prevenir de forma temprana la neumon?a como lo indica en su opini?n la profesional m?dico a la que recurrimos. Estos resultados mostraron que el prototipo logr? el objetivo principal, al dise?ar un equipo de prevenci?n contra la neumon?a. Pneumonia is the main cause of death in children under five years old, in the world. More deaths are estimated by pneumonia than HIV, malaria and measles. According to the high infant mortality rate from pneumonia; the main target of this thesis is design and implement an electronic prototype for early detection pneumonia in infants. For this purpose, I use a temperature sensor, the LM35, which was adapted to a medical electrode, in this way was attached to the patient?s body, also I use a magnetic sensor adapted to a rubber band, which was placed around the patient's chest. These sensors measure the body temperature in ?C and the number of breaths per minute (BPM), respectively. Both measurements were conditioned using the LM358N operational amplifier and processed using a PIC16F877A microcontroller. Data processed are transferred to a PC by an USB communication interface. Previously, in a Desktop computer was installed a software application developed in Visual Basic, which it has a graphical interface and test?s result is visualized. The tests were performed with seven children of different ages, of which I will mention only three cases. The fourth test was performed with a two years old boy, resulting in a body temperature of 39 ?C, 37 BPM and as a diagnostic, body temperature is over and close to tachypnea. The fifth test was performed with a four years old boy, resulting in a body temperature of 39 ?C, 31 BPM and as a diagnostic, body temperature is over and close to tachypnea. The seventh test was performed on a baby girl of 1 year old, resulting in a body temperature of 39 ?C, 34 BPM and as a diagnostic, body temperature is over and close to tachypnea, focusing on these results, these are the necessary conditions to prevent such early pneumonia according to opinion of professional medical that support me. These results showed that the prototype achieved the main objective, to design a prevention equipment against pneumonia.
Discipline: Ingenier?a Electr?nica
Grade or title grantor: Universidad Ricardo Palma. Facultad de Ingenier?a. Escuela Profesional de Ingenier?a Electr?nica
Grade or title: Ingeniero Electr?nico
Register date: 8-Aug-2019



This item is licensed under a Creative Commons License Creative Commons