Título: Niveles basales de glucosa sangu?nea en caballos pura sangre de carrera del Hip?dromo de Monterrico
Asesor(es): Collao, Jos? Luis; Collao, Jos? Luis
Campo OCDE: https://purl.org/pe-repo/ocde/ford#4.03.01
Fecha de publicación: 2017
Institución: Universidad Ricardo Palma - URP
Resumen: La presente investigaci?n tuvo por objetivo determinar los niveles de glucosa sangu?nea mediante el m?todo de medici?n de bioqu?mica sangu?nea y por el m?todo de gluc?metro en Caballos Pura Sangre de Carrera (PSC) entre 2 a 8 a?os de edad del Hip?dromo de Monterrico, con la finalidad de poder identificar la existencia de cualquier enfermedad metab?lica. Para el prop?sito se utilizaron 90 caballos PSC, machos y hembras entre 2 a 8 a?os de edad aparentemente sanos, obteniendo de cada animal una muestra de 3ml de sangre entera la cual fue transferida a un tubo vacutainer EDTA-F glucosa, para el an?lisis sangu?neo en laboratorio y se utiliz? una gota de sangre entera para la medici?n de glucosa en el analizador port?til. Los resultados de los niveles de glucosa sangu?nea obtenidos fueron: 87.57 mg/dL para el m?todo de medici?n por gluc?metro y 96.40 mg/dL para el m?todo de medici?n por bioqu?mica sangu?nea, los cuales no tuvieron una diferencia significativa (p>0.05). Con respecto a la edad se determin? que no hay diferencia estad?stica significativa con el m?todo de medici?n por gluc?metro (p<0.05), sin embargo por el m?todo de bioqu?mica sangu?nea si hubo una diferencia estad?stica significativa (p<0.05). Por ultimo en relaci?n al sexo no hubo una diferencia estad?stica significativa (p>0.05).
The objective of the present investigation was to determinated blood glucose levels using the blood biochemistry measurement method and by the glucometer method in Thoroughbreds (PSC) between 2 to 8 years old of the Monterrico racehorse, with the purpose of being able to identify the existence of any metabolic disease. For the purpose, 90 PSC male and female horses between 2 and 8 years were apparently healthy, obtaining from each animal a sample of 3 ml of whole blood which was transferred to a vacuum EDTA-F glucose vacutainer tube for blood analysis in the laboratory and one drop of whole blood was used for the measurement of glucose in the portable analyzer. The results obtained of blood glucose levels were: 87.57 mg/dL for the method of measurement by glucometer and 96.40 mg / dL for the method of measurement by blood biochemistry, which did not have a significant difference (p> 0.05). Regarding the age, it was determined that there was no significant statistical difference with the method of measurement by glucometer (p <0.05), however using the blood biochemistry method there was a significant statistical difference (p <0.05). Finally, in relation to gender, there was no statistically significant difference (p> 0.05)
Disciplina académico-profesional: Medicina Veterinaria
Institución que otorga el grado o título: Universidad Ricardo Palma. Facultad de Ciencias Biol?gicas. Escuela Profesional de Ciencias Veterinarias
Grado o título: M?dica Veterinaria
Fecha de registro: 22-nov-2017; 22-nov-2017