Buscar en Google Scholar
Título: Evaluación de la calidad del concreto en viviendas informales en Prolongación Las Quintas Sector I Distrito La Victoria -Chiclayo 2022
Asesor(es): Lorren Palomino, Angel Alberto
Campo OCDE: http://purl.org/pe-repo/ocde/ford#2.01.00
Fecha de publicación: 2024
Institución: Universidad Católica Santo Toribio de Mogrovejo
Resumen: La presente investigación tiene como objetivo general determinar la calidad del concreto en obras de autoconstrucción de viviendas que se encontraban realizando en el Sector I del distrito de la Victoria y determinar si el concreto que se elabora en las obras cumplen con los requerimientos normativos. Dentro de esta investigación se desarrolló, analizando la calidad del concreto que se vinieron efectuando, evaluando así el día de los vaciados datos, a través de unas fichas, detallando los puntos de interés y tomando; así por cada obra se adquirió muestras de sus agregados y a su vez se realizaron 3 probetas en obra para conocer la resistencia diseñada de la estructura vaciada. Para el desarrollo de esta investigación se llevó a cabo un muestreo, en el cual fueron seleccionadas 10 obras que se encontraban en construcción. Se hizo una comparación entre los datos obtenidos en campo y el proceso constructivo que efectuaban los maestros para conocer si cumplían con los requisitos mínimos que nos da la Norma E 0.60. Finalmente, se llegó a la conclusión que el concreto que ejecutaban en el lugar de investigación no llega a la resistencia requerida de 210 kg/cm para elementos estructurales, debido a esto se propuso un diseño de mezcla con en volumen de baldes, así en basándonos en esa medida poder lograr obtener la resistencia requerida. Además de los errores que se encontraron en las construcciones, se efectuó una propuesta de guía donde indican los puntos clave para una correcta elaboración del concreto.

This research presents two general objectives: determining the quality of the concrete in selfbuild housing projects that were being carried out in Prolongación la Quintas, Zone I of La Victoria District, and checking if the concrete produced in these projects meet the regulatory requirements. On the one hand, in this study, a correct pouring evaluation on construction work was done through some forms that allowed detailing the points of interest, for instance, the dosage. On the other hand, samples of aggregates were acquired from each construction work, and in turn, 3 graduated cylinders were taken from it, which after being subjected to the respective tests, allowed to identify the designed resistance of the poured structure. For the development of this research, a sampling was performed in 10 previously selected construction works. Considering the E.060 standard, a data evaluation, obtained from the field research and the construction process executed by the master builders, was done in order to determine whether they meet the minimum requirements established in that standard. Finally, it was concluded that the concrete used at the research work site did not reach the required resistance for structural elements being 210 kg/cm2. Consequently, a mixing design was proposed, detailing the volume of buckets, to obtain the required resistance. Besides the malpractices found in the construction works, a guide proposal was made, in which key points for an adequate concrete fabrication are indicated.
Disciplina académico-profesional: Ingeniería Civil Ambiental
Institución que otorga el grado o título: Universidad Católica Santo Toribio de Mogrovejo. Facultad de Ingeniería
Grado o título: Ingeniero Civil Ambiental
Jurado: Gamarra Uceda, Héctor Augusto; Céspedes Deza, José Alfredo Rolando; Lorren Palomino, Angel Alberto
Fecha de registro: 31-may-2024



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons