Bibliographic citations
This is an automatically generated citacion. Modify it if you see fit
Göpfert, J., (2021). Model-based fault diagnosis via structural analysis of a reverse osmosis plant [Pontificia Universidad Católica del Perú]. http://hdl.handle.net/20.500.12404/19043
Göpfert, J., Model-based fault diagnosis via structural analysis of a reverse osmosis plant []. PE: Pontificia Universidad Católica del Perú; 2021. http://hdl.handle.net/20.500.12404/19043
@mastersthesis{renati/536233,
title = "Model-based fault diagnosis via structural analysis of a reverse osmosis plant",
author = "Göpfert, Johannes Georg",
publisher = "Pontificia Universidad Católica del Perú",
year = "2021"
}
Full metadata record
Pérez Zúñiga, Carlos Gustavo
Reger, Johann
Göpfert, Johannes Georg
2021-05-11T17:31:24Z
2021-05-11T17:31:24Z
2021
2021-05-11
http://hdl.handle.net/20.500.12404/19043
Water desalination is one approach to force water scarcity. One of the processes used for
desalination is reverse osmosis. Like other systems, a reverse osmosis plant is susceptible to
faults. A fault can lead to a loss of efficiency, or if the fault is severe to a total breakdown.
Appropriate measures can minimize the impact of faults, but this requires in time fault
detection.
The following thesis shows a proposal for an online fault diagnosis system of a reverse
osmosis plant. For the model-based approach, a mathematical model of a reverse osmosis
plant has been developed. The model contains a new approach for modeling the interaction
between the high-pressure pump, the brine valve, and the membrane module. Furthermore,
six faults considered for fault diagnosis have been modeled. Two of the faults are plant
faults: The leakage of the feed stream and membrane fouling. The other four faults are
sensor or actuator malfunctions.
The fault diagnosis system is developed via structural analysis, a graph-based approach to
determine a mathematical model’s overdetermined systems of equations.
With the structural analysis, 73 fault-driven minimal structurally overdetermined (FMSO)
sets have been determined. The results show that all six faults are detectable. However, two
faults are not isolable. Five of the FMSO sets have been chosen to deduce the residuals used
for online fault detection and isolation. The simulations demonstrate that the calculated
residuals are appropriate to detect and isolate the faults. If one assumes that only the
considered faults occur, it is possible to determine some faults’ magnitude. (es_ES)
eng (es_ES)
Pontificia Universidad Católica del Perú (es_ES)
info:eu-repo/semantics/openAccess (es_ES)
http://creativecommons.org/licenses/by-sa/2.5/pe/ (*)
Agua--Tratamiento--Ósmosis inversa (es_ES)
Modelos matemáticos (es_ES)
Fallas estructurales (es_ES)
Model-based fault diagnosis via structural analysis of a reverse osmosis plant (es_ES)
info:eu-repo/semantics/masterThesis (es_ES)
Pontificia Universidad Católica del Perú. Escuela de Posgrado. (es_ES)
Ingeniería de Control y Automatización (es_ES)
Maestría (es_ES)
Maestro en Ingeniería de Control y Automatización (es_ES)
PE (es_ES)
http://purl.org/pe-repo/ocde/ford#2.02.03 (es_ES)
https://purl.org/pe-repo/renati/level#maestro (es_ES)
41864666
https://orcid.org/0000-0001-5946-1395 (es_ES)
- (es_ES)
DE / CH91G6Y66
CH9WPZR41
712037 (es_ES)
Reger, Johann
Pérez Zúñiga, Carlos Gustavo
Sotomayor Moriano, Juan Javier
http://purl.org/pe-repo/renati/type#tesis (es_ES)
Privada asociativa
This item is licensed under a Creative Commons License