Buscar en Google Scholar
Título: Resistencia a la compresión de concreto f’c = 210 kg/cm2 empleando el 7% y 9 % de vidrio molido, Cajamarca 2023
Asesor(es): Salazar Huamán, Erlyn Giordany
Campo OCDE: https://purl.org/pe-repo/ocde/ford#2.01.01
Fecha de publicación: 16-nov-2023
Institución: Universidad Privada del Norte
Resumen: La presente de investigación tiene como objetivo general determinar la resistencia a la compresión del concreto al adicionar el 7% y 9% de vidrio molido en un concreto convencional f’c=210 kg/cm2. El tipo de investigación es correlacional, presentando un nivel del tipo aplicativa, y se basa en un diseño del modo experimental. La metodología consistió en realizar los respectivos análisis de los requerimientos de los agregados, así como la obtención del vidrio para su posterior uso. Como resultados se obtuvieron las características de los agregados en el laboratorio de la Universidad Privada del Norte, posteriormente, se obtuvieron los resultados de las resistencias promedio a la compresión axial del concreto a los 7, 14, 21 y 28 días de curado. Donde se pudo concluir que, al reemplazar el agregado fino por un 7% y 9% de vidrio molido, ambos porcentajes contribuyen en el aumento de la resistencia a la compresión del concreto, sin embargo, al reemplazar por el 9% el material logra tener un mejor comportamiento para aumentar su resistencia a la compresión del concreto convencional f’c = 210 kg/cm2.

The general objective of this research is to determine the compressive strength of concrete by adding 7% and 9% of ground glass in conventional concrete f'c=210 kg/cm2. The type of research is correlational, presenting an applicative type level, and is based on an experimental mode design. The methodology consisted of carrying out the respective analysis of the requirements of the aggregates, as well as obtaining the glass for its subsequent use. As results, the characteristics of the aggregates were obtained in the laboratory of the Universidad Privada del Norte, later, the results of the average resistance to axial compression of the concrete at 7, 14, 21 and 28 days of curing were obtained. Where it was possible to conclude that, when replacing the fine aggregate with 7% and 9% of ground glass, both percentages contribute to the increase in the compressive strength of the concrete, however, when replacing it with 9%, the material manages to have a better behavior to increase its resistance to compression than conventional concrete f'c= 210 kg/cm2.
Enlace al repositorio: https://hdl.handle.net/11537/35039
Disciplina académico-profesional: Ingeniería Civil
Institución que otorga el grado o título: Universidad Privada del Norte. Facultad de Ingeniería
Grado o título: Ingeniero Civil
Jurado: Cuadros Rojas, Héctor Arturo; Guillén Sheen, Tulio; Calua Carrasco, Carlos
Fecha de registro: 17-nov-2023



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons