Citas bibligráficas
Acosta, J., Vasquez, T. (2022). Mejora del sistema de aseguramiento y control de calidad QA/QC en el análisis de muestras Blast Hole, en la empresa Pan American Silver – U. M. La Arena S. A. 2022 [Tesis, Universidad Privada del Norte]. https://hdl.handle.net/11537/33902
Acosta, J., Vasquez, T. Mejora del sistema de aseguramiento y control de calidad QA/QC en el análisis de muestras Blast Hole, en la empresa Pan American Silver – U. M. La Arena S. A. 2022 [Tesis]. PE: Universidad Privada del Norte; 2022. https://hdl.handle.net/11537/33902
@misc{renati/524378,
title = "Mejora del sistema de aseguramiento y control de calidad QA/QC en el análisis de muestras Blast Hole, en la empresa Pan American Silver – U. M. La Arena S. A. 2022",
author = "Vasquez Campos, Thania Melani",
publisher = "Universidad Privada del Norte",
year = "2022"
}
The main objective of this research is to ensure and control the QA/QC quality in the analysis of blast hole samples, in the company Pan American Silver – U.M. La Arena S.A, preventing and detecting errors in sampling, preparation processes, analysis and reporting of samples by the primary laboratory. The design used is of a non-experimental transectional exploratory type, since it is based on the chemical results of the samples obtained that were not manipulated, were obtained in a single moment and will serve to begin to know phenomena about a new problem. Quality Control charts for Blast hole Sampling Precision, Accuracy and Contamination were prepared, validated and analyzed. In this investigation, a total of 5,643 Blast hole samples were evaluated, of which 2,154 were field duplicates, which represents a randomly distributed insertion ratio of 10.52%, which is good and acceptable. In precision, the error rate of the results of Field Duplicates was less than 10%. In Accuracy, the Bias was less than 10%. In Contamination, the evaluation of the preparation of samples with thick blanks was less than 5%. The effect of the improvement of the QA/QC control and assurance system in the analysis of blast hole samples will increase the confidence level of the laboratory results. As a final result, timely measures were proposed to solve problems identified in the sampling and chemical analysis.
IMPORTANTE
La información contenida en este registro es de entera responsabilidad de la universidad, institución o escuela de educación superior que administra el repositorio académico digital donde se encuentra el trabajo de investigación y/o proyecto, los cuales son conducentes a optar títulos profesionales y grados académicos. SUNEDU no se hace responsable por los contenidos accesibles a través del Registro Nacional de Trabajos de Investigación – RENATI.