Look-up in Google Scholar
Title: Mejora del sistema de aseguramiento y control de calidad QA/QC en el análisis de muestras Blast Hole, en la empresa Pan American Silver – U. M. La Arena S. A. 2022
Advisor(s): Portilla Castañeda, Miguel Ricardo
OCDE field: https://purl.org/pe-repo/ocde/ford#2.07.01
Issue Date: 29-Dec-2022
Institution: Universidad Privada del Norte
Abstract: La presente investigación, tiene como objetivo principal asegurar y controlar la calidad QA/QC en el análisis de muestras blast hole, en la empresa Pan American Silver – U.M. La Arena S.A, previniendo y detectando errores en el muestreo, procesos de preparación, análisis y reporte de muestras por parte de laboratorio primario. El diseño utilizado es de tipo no experimental transeccional exploratorio, ya que se basa en los resultados químicos de las muestras obtenidas que no fueron manipuladas, fueron obtenidas en un único momento y servirá para comenzar a conocer fenómenos sobre un problema nuevo. Se elaboró, validó y analizó gráficos de Control de Calidad para la Precisión, Exactitud y Contaminación del Muestreo de Blast holes. En esta investigación se evaluó un total de 5643 muestras Blast hole, de las cuales 2154 fueron duplicados de campo, lo que representa un ratio de inserción de 10.52% distribuidos aleatoriamente, el cual es bueno y aceptable. En precisión, la tasa de errores de los resultados de Duplicados de Campo fue menor a 10%. En Exactitud el Sesgo fue menor a 10%. En Contaminación, la evaluación de la preparación de muestras con blancos gruesos fue menor a 5%. El efecto de la mejora del sistema de control y aseguramiento QA/QC en el análisis de muestras blast hole aumentará el nivel de confianza de los resultados de laboratorio. Como resultado final se propuso medidas oportunas para solucionar problemas identificados en el muestreo y análisis químico.

The main objective of this research is to ensure and control the QA/QC quality in the analysis of blast hole samples, in the company Pan American Silver – U.M. La Arena S.A, preventing and detecting errors in sampling, preparation processes, analysis and reporting of samples by the primary laboratory. The design used is of a non-experimental transectional exploratory type, since it is based on the chemical results of the samples obtained that were not manipulated, were obtained in a single moment and will serve to begin to know phenomena about a new problem. Quality Control charts for Blast hole Sampling Precision, Accuracy and Contamination were prepared, validated and analyzed. In this investigation, a total of 5,643 Blast hole samples were evaluated, of which 2,154 were field duplicates, which represents a randomly distributed insertion ratio of 10.52%, which is good and acceptable. In precision, the error rate of the results of Field Duplicates was less than 10%. In Accuracy, the Bias was less than 10%. In Contamination, the evaluation of the preparation of samples with thick blanks was less than 5%. The effect of the improvement of the QA/QC control and assurance system in the analysis of blast hole samples will increase the confidence level of the laboratory results. As a final result, timely measures were proposed to solve problems identified in the sampling and chemical analysis.
Note: El informe de similitud se encuentra ubicado en el último archivo con acceso restringido; además, como parte de los metadatos, se incluye el porcentaje de similitud (opción Mostrar el registro completo del ítem).
Discipline: Ingeniería Geológica
Grade or title grantor: Universidad Privada del Norte. Facultad de Ingeniería
Grade or title: Ingeniero Geólogo
Juror: Alva Huamán, Daniel Alejandro; Álvarez León, Víctor Eduardo; Chuquirruna Chávez, Wilder
Register date: 2-Aug-2023



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.