Look-up in Google Scholar
Title: Diseño Estructural de una Edificación de Oficinas de 5 Pisos + 2 Sótanos en Lima empleando el Análisis estático No Lineal Pushover
Other Titles: Structural Design of a 5-Story Office Building with 2 Basements in Lima Using Nonlinear Static Pushover Analysis
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Issue Date: 22-Jun-2024
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: Esta investigación se realizó con la finalidad de mostrar los beneficios obtenidos de realizar un análisis de desempeño sísmicos para edificios destinados a oficinas en Lima. El caso de estudio fue una edificación de 5 pisos + 2 sótanos. Inició con el predimensionamiento y modelamiento estructural conforme a la norma E.020 del RNE (2006), seguido por un análisis sísmico lineal según la norma E.030 (2018). Los elementos estructurales principales fueron diseñados bajo la normativa E.060 del RNE (2009). Se realizó un análisis estático no lineal Pushover conforme a ASCE 41-13 (2014) para evaluar el desempeño estructural bajo cargas sísmicas graduales. Los resultados mostraron cumplimiento con los requisitos de operación y seguridad de vida según los criterios de Visión 2000 (1995), destacando una adecuada resistencia ante sismos frecuentes y ocasionales, y expectativa de daños controlados bajo sismos raros y muy raros en ambas direcciones. Concluyó que la estructura está diseñada para proteger la vida humana y garantizar la funcionalidad durante eventos sísmicos severos.

This research was conducted to demonstrate the benefits of performing seismic performance analysis for office buildings in Lima. The case study involved a 5-story building with 2 basements. It began with preliminary sizing and structural modeling according to the E.020 standard of the National Building Code (RNE) (2006), followed by linear seismic analysis as per the E.030 standard (2018). The main structural elements were designed under the E.060 standard of the RNE (2009). A nonlinear static Pushover analysis was conducted following ASCE 41-13 (2014) to assess structural performance under gradual seismic loads. The results demonstrated compliance with operational and life safety requirements according to Vision 2000 (1995) criteria, highlighting adequate resistance to frequent and occasional earthquakes, with controlled damage expectations under rare and very rare earthquakes in both directions. It concluded that the structure is designed to protect human life and ensure functionality during severe seismic events.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Serrano Lazo, Malena Alessandra; Moreno Sánchez, Javier Daniel
Register date: 27-Aug-2024



This item is licensed under a Creative Commons License Creative Commons