Buscar en Google Scholar
Título: Validación del sistema de cadena de frío en la logística de medicamentos y reactivos de 2ºC a 8ºC : Perú : enero-junio 2007
Asesor(es): Castillo Calle, Alfredo Alonzo
Campo OCDE: https://purl.org/pe-repo/ocde/ford#3.01.05
Fecha de publicación: 2007
Institución: Universidad Nacional Mayor de San Marcos
Resumen: La Logística de la Cadena de Frío se ha convertido en una herramienta imprescindible al momento de garantizar la calidad y la efectividad, tanto de los medicamentos, como de los reactivos para su óptimo estado de conservación a parámetros de temperatura preestablecidos. Por lo tanto, a través del presente trabajo se ha desarrollado y validado un método para la correcta distribución y conservación, tanto del producto farmacéutico terminado, como del reactivo que requiere un rango específico de temperatura de 2-8º C. Se procedió a elaborar los protocolos donde se definen los objetivos específicos de las evaluaciones a efectuar. Se estableció el plan de monitoreo respectivo, y las condiciones para el embalaje; así como la comparación de resultados con los rangos preestablecidos. En la etapa de la validación en sí, se realizó una evaluación del sistema y se hicieron las pruebas que garantizan que todos los componentes funcionen según lo especificado. Se sometió a prueba todos los controles de operación tales como: El buen desempeño del compresor. El buen desempeño del Sistema de Alarma de la Cámara Fría específica para 2°C - 8º C. El buen desempeño del TempTale4 el cual nos permite chequear la trazabilidad del comportamiento de la temperatura desde el punto de origen hasta el punto de destino.

The Logistics of the Chain of Cold has become in one indispensable tool at the moment to guarantee the quality and the efficiency, so much of the medicines, like of the reagents for them ideal condition of conservation to pre-established parameters of temperature. Therefore, in this present work has developed a method validated for the correct distribution and conservation, so much of the finished pharmaceutical product, as of the reagent that needs a specific range of temperature of 2-8 º C. It was elaborated the protocols where it’s defined the specific aims of the evaluations to effect, developing a plan of monitoring. The conditions adapted for a correct distribution of the product to refreshed temperature. In the stage of the validation, it was realized an evaluation of the system and It was developed the tests which guarantee that all the components work according to the specified. It was tested all the operational controls such as: The good performance of the Cold Chamber formed to specific range of temperature from 2°C to 8°C; so the good performance of the Freezer formed to specific range of temperature from –18°C to –28°C; and the good performance of the TempTale4 and software, device selected with the purpose to check the behavior of the temperature from the point of origin up to the point of destiny.
Disciplina académico-profesional: Farmacia y Bioquímica
Institución que otorga el grado o título: Universidad Nacional Mayor de San Marcos. Facultad de Farmacia y Bioquímica. Escuela Académico Profesional de Farmacia y Bioquímica
Grado o título: Químico Farmacéutico
Fecha de registro: 20-ago-2013



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons