Citas bibligráficas
Vela, F., (2005). Validación de un sistema de apoyo crítico en la industria farmacéutica : vapor para uso farmacéutico [Tesis, Universidad Nacional Mayor de San Marcos]. https://hdl.handle.net/20.500.12672/2606
Vela, F., Validación de un sistema de apoyo crítico en la industria farmacéutica : vapor para uso farmacéutico [Tesis]. PE: Universidad Nacional Mayor de San Marcos; 2005. https://hdl.handle.net/20.500.12672/2606
@misc{renati/479174,
title = "Validación de un sistema de apoyo crítico en la industria farmacéutica : vapor para uso farmacéutico",
author = "Vela García, Friggens",
publisher = "Universidad Nacional Mayor de San Marcos",
year = "2005"
}
-- The present work shows the form to develop the validation of one of the pillars within the system of critical support in the pharmaceutical industry: the Prospective Validation of the Generating Clean Steam System, in order to establish documentary evidence that the process is able to fulfill in consistent and repetitive form the established specifications. The protocols were elaborated in which the specific objectives of the evaluations, the responsibilities of each of the involved areas are defined to carry out; interest variables to monitor were established including the respective plan of monitoring; besides to sit includes the acceptance criterias which will be compared with the expected results afterwards. Then, the validation process itself was developed, in which an evaluation of the process was made and all the components of the system were tested to check whether they work according to the specifications or not. All the controls of normal operation were checked, verification: of the generating system, of the control system, alarms, pump, and water levels. The qualification of performance was made, for which analyzed the purity profile was analyzed: physical-chemistry control (pH, conductivity, rusty substances and total solid) and microbiological control (test of endotoxins and microbial load) of the condensed steam in the point of use by 30 days. With the obtained results we conclude that the steam produced by the clean steam generator in a local pharmaceutical industry is suitable for its use. -- Key Words: Validation, System, Generator, Steam, Purity.
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons