Look-up in Google Scholar
Title: Análisis de la influencia de losas de entrepisos en respuesta sísmica de los edificios multifamiliares aplicando la norma peruana
Other Titles: Analysis of the influence of mezzanine slabs on seismic response of multifamily buildings applying the Peruvian standard
Advisor(s): Moreno Sánchez, Javier Daniel
OCDE field: https://purl.org/pe-repo/ocde/ford#2.00.00; https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 27-Dec-2022
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: El presente trabajo de investigación busca determinar la variación de pesos que existe en las losas aligeradas, cuál sería la reducción de la fuerza sísmica debido al cambio de sistema. Existen estudios referidos al costo beneficio del uso de estos nuevos sistemas, pero pocos referidos a determinar claramente la respuesta sísmica ante una demanda de un sismo de gran magnitud. Por ello se propone hacer diseño análisis sísmico en tres edificios multifamiliares y aplicarle sobrecargas actuantes, determinar cuál es el peso, fuerza sísmica, derivas con los diferentes sistemas, como son las viguetas pretensadas Firth, Prelosas, losas convencional y Vigacero. A través de la evaluación mediante modelos tridimensionales y usando el software Etabs se obtendrán ratios comparativas para poder obtener resultados que servirán de guía para la toma adecuada en el diseño estructural, siguiendo las prescripciones de la norma E.030 sismorresistente se evaluarán entrepisos con sistema de viguetas pretensadas, Prelosas o el sistema de losa Vigacero. Con ello se propone implementar una solución más eficiente al diseño estructural utilizando las diferentes alternativas propuestas.

The present research work seeks to determine the variation of weights that exists in the lightened slabs, which would be the reduction of the seismic force due to the change of system. There are studies referring to the cost benefit of the use of these new systems, but few refer to clearly determining the seismic response to a demand of a large magnitude earthquake. For this reason, it is proposed to carry out a seismic analysis design in three multi-family buildings and apply acting overloads, determine the weight, seismic force, drifts with the different systems, such as the Firth prestressed joists, Pre-slabs, conventional slabs and steel beam. Through the evaluation through three-dimensional models and using the Etabs software, comparative ratios will be obtained in order to obtain results that will serve as a guide for the adequate decision in the structural design, following the prescriptions of the seismic-resistant standard E.030, mezzanines with a system of prestressed joists, precast slab or the slab beam system. With this, it is proposed to implement a more efficient solution to the structural design using the different proposed alternatives.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). División de Estudios Profesionales para Ejecutivos (EPE)
Grade or title: Ingeniero Civil
Juror: Rodriguez Dionisio, Sandra; Silvera Lima, Manuel; Torres Diaz, Víctor
Register date: 17-Apr-2023



This item is licensed under a Creative Commons License Creative Commons