Look-up in Google Scholar
Title: Estudio comparativo del comportamiento sísmico de una edificación reforzada con muros de concreto armado y con disipadores de fluido viscoso
Advisor(s): Burgos Namuche, Maribel
Issue Date: 12-Mar-2020
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: La presente tesis, está enfocada al estudio del comportamiento sísmico comparativo de una edificación reforzada con muros de concreto armado y disipadores de fluido viscoso para evaluar su efectividad desde el punto de vista estructural. Por ello, se ha evaluado la estructura existente para verificar la necesidad de reforzar. Luego, se ha evaluado el edificio incorporando muros estructurales para determinar su comportamiento sísmico. También, se ha evaluado el edificio añadiendo disipadores, para ello se tuvo en cuenta la ubicación de los dispositivos con los valores del coeficiente de amortiguamiento, y de ese modo analizar el comportamiento sísmico. De acuerdo a la evaluación, se obtuvo una reducción máxima de distorsiones del 74% y 76% en X para el edificio con muros y disipadores respectivamente, y para Y el 65% en el edificio con muros y el 56% con disipadores en ambos casos comparados con la estructura actual. De los resultados, se puede apreciar que en ambos reforzamientos las distorsiones se reducen cumpliendo con lo permisible. Asimismo, en relación a las cortantes se obtuvo que en el edificio con muros incrementa en 143% al edificio existente, sin embargo, los desplazamientos se disminuyen; y en el reforzamiento con disipadores se reducen en 26% en comparación al edificio en estudio, ello es de gran relevancia debido a que los elementos estructurales van a soportar menor fuerza sísmica. Por lo tanto, la propuesta con disipadores es la más efectiva, debido a que posee menor intervención de área y reduce el movimiento sísmico en la estructura.

This thesis is focused on the study of comparative seismic behavior of a building reinforced with concrete walls and fluid viscous dampers to evaluate its structural effectiveness. Therefore, the existing structure has been evaluated to verify the need for reinforcement. The building has then been evaluated incorporating structural walls to determine its seismic behavior. Also, the building has been evaluated by adding fluid viscous dampers, for this took into account the location of the devices with the values ​​of the damping coefficient, and thus analyze the seismic behavior. According to the evaluation, a maximum reduction of distortions of 74% and 76% in X was obtained for the building with walls and dampers respectively, and for Y the 65% in the building with walls and the 56% with dampers in both cases compared to the current structure. From the results, it can be seen that in both reinforcements the distortions are reduced by complying with the permissible. Also, in relation to the forces, it was obtained that in the building with walls increases in 143% to the existing building, however, the displacements are decreased; and in the reinforcement with dissipaters are reduced by 26% compared to the building under study, this is of great relevance because the structural elements will withstand less seismic force. Therefore, the proposal with fluid viscous dampers is the most effective, because it has less area intervention and reduces the seismic movement in the structure.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de ingeniería
Grade or title: Ingeniero Civil
Register date: 24-Aug-2020



This item is licensed under a Creative Commons License Creative Commons