Citas bibligráficas
Gutiérrez, R., (2019). Efecto de diferentes concentraciones de biol como enraizador en estacas de vid (Vitis vinífera L.) patrón Harmoney, en condiciones del Valle de Virú [Tesis, Universidad Privada Antenor Orrego - UPAO]. https://hdl.handle.net/20.500.12759/4809
Gutiérrez, R., Efecto de diferentes concentraciones de biol como enraizador en estacas de vid (Vitis vinífera L.) patrón Harmoney, en condiciones del Valle de Virú [Tesis]. : Universidad Privada Antenor Orrego - UPAO; 2019. https://hdl.handle.net/20.500.12759/4809
@misc{renati/380826,
title = "Efecto de diferentes concentraciones de biol como enraizador en estacas de vid (Vitis vinífera L.) patrón Harmoney, en condiciones del Valle de Virú",
author = "Gutiérrez Mariños, Rosmy Alexander",
publisher = "Universidad Privada Antenor Orrego - UPAO",
year = "2019"
}
This research was carried out in the area of Viru, Viru province in which determined the effect of different concentrations of Biol as enraizador in cuttings of Grapevine (Vitis vinifera L.) pattern Harmoney. The research was divided into five treatments and five replications with the same amount of liquid for each treatment, resulting in T1 witness which was applied 1 litre of water, followed the T2, T3, T4 and T5 a dose of 20% of Biol, 40% of Biol, Biol 60% and 80% of Biol respectively. For the number of cuttings with roots parameter was obtained a mean statistic of 1.25 units, 0 units, 0 units, 0.25 units and 0.50 units for the witness, T2, T3, T4, T5, respectively. For the number of cuttings without roots and were obtained a mean statistic of 18 units, 20 units, 20 units, 19.75 units 19.25 units for the witness, T2, T3, T4, T5 respectively. An average 3.25 statistics was found regarding the number of roots per stake units, 0 units, 0 units, 0.25 units and 5.25 units for the witness, T2, T3, T4, T5, respectively. In relation to the length of root by stake was recorded a mean statistic of 3.37 cm, 0 cm, 0 cm, 0.12 cm and 2 cm for the witness, T2, T3, T4, T5, respectively. In the parameter number of shoots per stake be found an average of 1.66 units, 1.41 units, 1.58 units, 2.18 units and 0.79 units for the witness, T2, T3, T4, T5, respectively. For the parameter of shoot length was obtained an average of 1.60 cm, 1.01 cm, 1.59 cm, 1.76 cm and 2.01 cm for the witness, T2, T3, T4, T5, respectively.
IMPORTANTE
La información contenida en este registro es de entera responsabilidad de la universidad, institución o escuela de educación superior que administra el repositorio académico digital donde se encuentra el trabajo de investigación y/o proyecto, los cuales son conducentes a optar títulos profesionales y grados académicos. SUNEDU no se hace responsable por los contenidos accesibles a través del Registro Nacional de Trabajos de Investigación – RENATI.