En esta investigación se estudió las características de las propiedades de unidades de albañilería y muretes conformados por bloques de concreto en adición de conchas de abanico para la ciudad de Trujillo. Se realizaron ensayos a los materiales que se iban a emplear en la fabricación de los bloques de concreto artesanal, donde se utilizó confitillo con un TMN de 3/8”de la cantera de “Huanchaco”, arena de 4.25mm a 0.076mm de la cantera de “Caballo Muerto”, cemento tipo I Pacasmayo y agua potable de Trujillo, además se realizó un estudio físico - químico a la concha de abanico en la Universidad de Trujillo (LASASI),para luego ser triturada y ser incorporada en los bloques de concreto. Para los análisis de agregados se realizó ensayos como: análisis granulométrico, contenido de humedad, absorción, peso específico, peso unitario suelto y peso unitario compactado para determinar sus propiedades y posteriormente realizar el diseño de mezcla con una dosificación 1: 3.44: 1.96 / 24.07 con una relación de agua/cemento de 0.55 de acuerdo a la ACI 211.1. Se fabricó bloque prototipos con las dimensiones de 14cm de ancho, 19cm de altura y 39cm de largo, siendo curados durante 7 primeros días para luego realizar las pilas y muretes con el fin de evaluar los ensayos que demanda la norma E.070 (2006), que constan de los ensayos de alabeo NTP 399.613, absorción, variación dimensional, resistencia a la compresión con la NTP 399.604, compresión axial de pilas NTP 399.605 y compresión diagonal de muretes NTP 399.621. En los ensayos se obtuvo que el bloque con incorporación de concha de abanico de 16% tuvo una resistencia a la compresión de 26.475 kg/cm2 siendo mayor en un 15 % al bloque patrón de 22.890 kg/cm2 superando la carga mínima establecida en la norma. Con respecto a los ensayos de variación dimensional, alabeo y absorción se obtuvo resultado que cumplieron con lo especificado en la norma. Además, se verificó que a mayor incorporación del 20% de concha de abanico la resistencia a la compresión disminuye. Finalmente, en los grupos de pilas y muretes ensayados se hizo una comparación con el ladrillo de arcilla King Kong artesanal obteniendo resultados menores con respecto a la resistencia mínima establecida en la norma. (spa)
In this investigation the characteristics of the properties of units of masonry and walls formed by concrete blocks in addition to shells of fan for the city of Trujillo were studied. Tests were carried out on the materials that were going to be used in the manufacture of artisanal concrete blocks, where confitillo was used with a TMN of 3/8 “from the quarry of“ Huanchaco “, sand from 4.25mm to 0.076mm from the quarry of “Caballo Muerto“, cement type I Pacasmayo and potable water of Trujillo, also a physical - chemical study was carried out on the fan shell at the University of Trujillo (LASASI), to be later crushed and incorporated into the blocks of concrete. For the analysis of aggregates, tests were carried out such as: granulometric analysis, moisture content, absorption, specific weight, loose unit weight and compacted unit weight to determine their properties and then perform the mixing design with a dosage 1: 3.44: 1.96 / 24.07 with a water / cement ratio of 0.55 according to ACI 211.1. Prototype block was made with the dimensions of 14cm wide, 19cm high and 39cm long, being cured for 7 first days to then make the piles and walls in order to evaluate the tests required by the E.070 (2006) , consisting of NTP 399.613 warping tests, absorption, dimensional variation, compression resistance with NTP 399.604, axial compression of NTP 399.605 piles and diagonal compression of NTP walls 399.621. In the tests it was obtained that the block with incorporation of 16% fan shell had a compressive strength of 26,475 kg / cm2 being 15% higher than the standard block of 22,890 kg / cm2 exceeding the minimum load established in the norm . Regarding the tests of dimensional variation, warping and absorption, results were obtained that complied with what is specified in the standard. In addition, it was verified that the greater incorporation of 20% of the fan shell, the compression resistance decreases. Finally, in the groups of piles and walls tested, a comparison was made with the handmade King Kong clay brick, obtaining lower results with respect to the minimum resistance established in the standard. (eng)
Tesis (spa)
application/pdf (eng)
spa (spa)
Universidad Privada Antenor Orrego - UPAO (spa)
T_ING.CIVIL_1703
info:eu-repo/semantics/openAccess (spa)
Universidad Privada Antenor Orrego (spa)
Repositorio institucional - UPAO (spa)
Bloque de concreto (spa)
Conchas de abanico (spa)
Ensayo y resistencia (spa)
Caracterización de las propiedades de unidades de albañilería y muretes conformados por bloques de concreto en adición de conchas de abanico. (spa)
info:eu-repo/semantics/bachelorThesis (spa)
Universidad Privada Antenor Orrego. Facultad de Ingeniería (spa)
Ingeniería Civil (spa)
Título Profesional (spa)
Ingeniero Civil (spa)
Privada asociativa



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.