Vasquez, B., Sanchez, B. (2023). Evaluación de dos pabellones considerando los efectos de interacción Tabique - Pórtico y columna corta de la I.E. 40230 “San Antonio del Pedregal“, ubicado en el distrito de Majes, provincia de Caylloma, Arequipa [Tesis, Universidad Privada Antenor Orrego - UPAO]. https://hdl.handle.net/20.500.12759/10377
Vasquez, B., Sanchez, B. Evaluación de dos pabellones considerando los efectos de interacción Tabique - Pórtico y columna corta de la I.E. 40230 “San Antonio del Pedregal“, ubicado en el distrito de Majes, provincia de Caylloma, Arequipa [Tesis]. PE: Universidad Privada Antenor Orrego - UPAO; 2023. https://hdl.handle.net/20.500.12759/10377
@misc{renati/377893,
title = "Evaluación de dos pabellones considerando los efectos de interacción Tabique - Pórtico y columna corta de la I.E. 40230 “San Antonio del Pedregal“, ubicado en el distrito de Majes, provincia de Caylloma, Arequipa",
author = "Sanchez Saavedra, Brayan Carlos",
publisher = "Universidad Privada Antenor Orrego - UPAO",
year = "2023"
}
This research thesis details the structural analysis of an educational institution located in the district of Majes, province of Caylloma Arequipa; ““San Antonio del Pedregal““, having as main objective the analysis and evaluation of the effects between the partition-portico and short column interaction of this type of buildings to provide optimal solutions to improve the structural behavior of the building intended for education, since the Peruvian technical standard classifies them as essential building and should remain standing in an earthquake of great magnitude. In the analysis process, field inspections were carried out with non-destructive technical tests to determine the geometric, physical and mechanical characteristics of the structural elements in order to evaluate the seismic behavior of the structure through a mathematical model, as well as to verify the types of failures or unfavorable effects that this building may present. The data obtained are developed and solved in the ETABS V20.1 modeling program, determining the deformations of frames, the shear resistance of the masonry, verifying the behavior of the wall when replacing it with an equivalent prop taking into account the crushing, diagonal tension and shear, also the walls that form the short columns were analyzed to verify the concentration of internal forces (shear and moments) in the free and restricted portions by the partition walls. After analyzing the results and performing all the corresponding verifications, a reinforcement of the building was proposed in order to have a better response to a seismic movement. With respect to the short column pathologies, it was decided to isolate the partition walls from the superstructure so as not to compromise the columns; in addition, a jacketing of the column was considered, increasing the camber and converting it into a T column. Finally, it was possible to demonstrate that the deformations of the portal frames in the braced zones in terms of displacements and shear forces show an increase of up to 4 times the shear force than in the short column zones
Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons