Buscar en Google Scholar
Título: Uso de macro-fibras de polipropileno y forma de agregado grueso en la tenacidad del concreto fabricado con cemento Portland tipo GU
Palabras clave: Macro fibrasPolipropileno
Fecha de publicación: 2018
Institución: Universidad Privada Antenor Orrego - UPAO
Resumen: En el presente trabajo se determinó la influencia de las macro-fibras de polipropileno y la forma del agregado grueso en la tenacidad del concreto fabricado con cemento portland tipo GU. Se elaboraron en total 90 probetas, según las normas UNE 83504 y UNE 83502, con 0, 3, 4, 6 y 8 kg de fibra de polipropileno por metro cúbico de concreto. El concreto se dosificó con relaciones a/c de 0.43, 0.48 y 0.55, agregado grueso de forma angular e irregular, con un tamaño máximo nominal de ¾”. A dichas probetas se las sometió al ensayo de doble punzonamiento en concordancia a la norma UNE 83515. Concluyendo que para las mezclas de concreto con agregado grueso de forma irregular y de tamaño máximo nominal de ¾”, se observó un incremento de la tenacidad conforme fue aumentando la dosificación de fibras, pero no logró optimizar de manera definida la tenacidad en el concreto; y para las mezclas de concreto con agregado grueso de forma angular y de tamaño máximo nominal de ¾”, obtuvieron el mayor incremento de latenacidad para una dosificación de 4 kg/mix3, siendo estas 504.50 Joules para una relación a/c de 0.43, 440.04 Joules para una relación a/c de 0.48 y 417.20 Joules para una relacióna/c de 0.55

In the present work, the influence of polypropylene macro-fibers and the shape of the coarse aggregate on the toughness of the concrete manufactured with portland type GU cement was determined. A total of 90 specimens were prepared, according to the UNE 83504 and UNE 83502 standards, with 0, 3, 4, 6 and 8 kg of polypropylene fiber per cubic meter of concrete. The concrete was dosed with a / c ratios of 0.43, 0.48 and 0.55, coarse aggregate of angular and irregular shape, with a maximum nominal size of ¾ ““. Said test tubes were subjected to the double punching test in accordance with the UNE 83515 standard. Concluding that for the mixtures of concrete with coarse aggregate of irregular shape and maximum nominal size of ¾ ““, an increase of the tenacity was observed as the dosage of fibers was increasing, but it did not manage to definitively optimize the tenacity in the concrete; and for concrete mixtures with coarse aggregate of angular shape and maximum nominal size of ¾ ““, they obtained the highest increase in toughness for a dosage of 4 kg / m3, these being 504.50 Joules for an a / c ratio of 0.43, 440.04 Joules for an a / c ratio of 0.48 and 417.20 Joules for an a / c ratio of 0.55.
Disciplina académico-profesional: Ingeniería Civil
Institución que otorga el grado o título: Universidad Privada Antenor Orrego. Facultad de Ingeniería
Grado o título: Ingeniero Civil
Fecha de registro: 6-jul-2018



IMPORTANTE
La información contenida en este registro es de entera responsabilidad de la universidad, institución o escuela de educación superior que administra el repositorio académico digital donde se encuentra el trabajo de investigación y/o proyecto, los cuales son conducentes a optar títulos profesionales y grados académicos. SUNEDU no se hace responsable por los contenidos accesibles a través del Registro Nacional de Trabajos de Investigación – RENATI.