Buscar en Google Scholar
Título: Microfiltracion in vitro de una resina fluida convencional y autoadhesiva
Asesor(es): Villarreal Becerra, Einer Niels
Fecha de publicación: 2014
Institución: Universidad Privada Antenor Orrego - UPAO
Resumen: Objetivo: Comparar el grado de microfiltración in vitro de una resina fluida convencional y autoadhesiva, en dientes anteriores de bovino. Materiales y Método: Los dos sistemas utilizados fueron: Grupo A resina fluida convencional (3MTM FiltekTM Z350 XT) y Grupo B resina autoadhesiva (DyadTM Flow Kerr). Se prepararon 30 dientes anteriores de bovino con cavidades clase V y se asignaron al azar en 2 grupos (Grupo A y B), con 15 dientes de bovino para cada grupo, se realizaron las restauraciones siguiendo las especificaciones del fabricante. Después de ser restauradas las muestras se sometieron a termociclado (300 ciclos entre 5°C y 55°C) en agua destilada y se sumergieron en una solución de azul de metileno al 2% durante 24 horas. Luego se lavaron, se secaron, se seccionaron y se analizaron en un microscopio estereoscópico con un aumento de 40X. Los datos resultantes se procesaron en el programa estadístico STATA versión 12, para luego presentar los resultados en tablas de doble entrada y gráficos. El test no paramétrico U de Mann-Whitney se usó para comparar la microfiltración en ambos tipos de resina fluida. Resultados: En los resultados de este estudio no se observaron diferencias estadísticamente significativas (p= 0.8457), en el grado de microfiltración de las resinas fluidas utilizadas. Conclusión: Se concluyó que no existe diferencia en el grado de microfiltración in vitro entre la resina fluida convencional y la resina fluida autoadhesiva.

Objective: Comparing the extent of in vitro microfiltration conventional flowable resin and self-adhesive, bovine anterior teeth. Materials and Methods: Materials and Methods: The two systems used were: Group A conventional flowable composite (Filtek Z350 3M ™ XT) and Group B self-adhesive resin (Flow DyadTM Kerr). Thirty bovine anterior teeth were prepared with class V cavities and were randomized into 2 groups (Group A and B), with 15 bovine teeth for each group, the restorations were performed following the manufacturer's specifications. Be restored after the samples were subjected to thermocycling (300 cycles between 5 ° C and 55 ° C) in distilled water and dipped in a solution of methylene blue at 2% during 24 hours. Then washed, dried, sectioned and examined under a stereoscopic microscope at a magnification of 40X. The resulting data were processed using the statistical program STATA version 12, and present the results in two-way tables and graphs. The nonparametric Mann-Whitney test was used to compare the microleakage in both types of fluid resin. Results: The results of this study no statistically significant difference (p = 0.8457) were observed in the degree of microleakage of flowable composites used. Conclusion: It was concluded that there is no difference in the degree of in vitro microleakage between conventional flowable resin and flowable resin self-adhesive.
Disciplina académico-profesional: Estomatología
Institución que otorga el grado o título: Universidad Privada Antenor Orrego. Facultad de Medicina Humana
Grado o título: Cirujano Dentista
Fecha de registro: 15-sep-2015



IMPORTANTE
La información contenida en este registro es de entera responsabilidad de la universidad, institución o escuela de educación superior que administra el repositorio académico digital donde se encuentra el trabajo de investigación y/o proyecto, los cuales son conducentes a optar títulos profesionales y grados académicos. SUNEDU no se hace responsable por los contenidos accesibles a través del Registro Nacional de Trabajos de Investigación – RENATI.