La presente tesis tiene como objetivo el desempeño sísmico de una edificación de albañilería confinada de cinco pisos para fines de hotelería, ubicado en el Distrito de Piura – Provincia de Piura – Región Piura; el cual se desarrollará a partir de la Arquitectura, compuesto de ambientes que se destinarán a habitaciones, oficinas, recepción, salas de conferencia, entre otros. Dicha edificación, destinada al servicio de hotelería, cuenta con un área del terreno de 217,84 𝑚�2. El desarrollo de este proyecto se llevó a cabo siguiendo los requisitos establecidos por las normas técnicas peruanas, específicamente las siguientes: E.020 Cargas, E.030 Diseño sismorresistente, E.060 Concreto Armado, E.070 Albañilería. Además, se tomaron en consideración normas internacionales como ACI 318-14 (American Concrete Institute), ASCE 41-17, ACI 318-19 y FEMA 440 (Federal Emergency Management Agency). Para el análisis estructural no lineal, se utilizó el método estático, aplicando cargas de gravedad a la estructura y cargas monotónicas en cada dirección para permitir que los materiales alcanzaran su estado no lineal y lograr así su rendimiento óptimo. Como resultado, se determinó que el desempeño sísmico en ambas direcciones fue de ““Completamente Operacional““, con cortantes de 779.52 toneladas y desplazamientos de 89.32 mm en la dirección ““X““, y una cortante de 802.89 toneladas y un desplazamiento de 92.64 mm en la dirección (es_PE)
The objective of this thesis is to study the seismic performance of a five- story confined masonry building designed for hotel purposes, located in the District of Piura, Province of Piura, Piura Region. The building will consist of various spaces such as rooms, offices, reception area, conference rooms, among others. The hotel building occupies a land area of 217.84 m2. The development of this project followed the requirements established by Peruvian technical standards, specifically the following: E.020 Loads, E.030 Seismic Design, E.060 Reinforced Concrete, E.070 Masonry. Additionally, international standards such as ACI 318-14 (American Concrete Institute), ASCE 41-17, ACI 318-19, and FEMA 440 (Federal Emergency Management Agency) were also considered. For the nonlinear structural analysis, the static method was used. Gravity loads were applied to the structure along with monotonic loads in each direction to allow the materials to reach their nonlinear state and achieve their optimal performance. The analysis determined that the seismic performance in both directions was rated as ““Fully Operational,““ with shear forces of 779.52 tons and displacements of 89.32 mm in the ““X““ direction, and a shear force of 802.89 tons and a displacement of 92.64 mm in the ““Y““ direction. (es_PE)
Tesis (es_PE)
application/pdf (es_PE)
spa (es_PE)
Universidad Privada Antenor Orrego (es_PE)
T_CIVIL_2464
info:eu-repo/semantics/openAccess (es_PE)
https://creativecommons.org/licenses/by/4.0/ (es_PE)
Desempeño Sismico (es_PE)
Rotulas de Corte (es_PE)
Desempeño sísmico de una edificación de albañilería confinada de 5 pisos en la calle Junín en la ciudad de Piura (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Privada Antenor Orrego. Facultad de Ingenieria (es_PE)
Ingenieria Civil (es_PE)
Ingeniero Civil (es_PE)
PE (es_PE)
http://purl.org/pe-repo/ocde/ford#2.01.00 (es_PE)
http://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
40539624
https://orcid.org/0000-0002-3441-8005 (es_PE)
73216637
732016 (es_PE)
Cancino Rodas, Cesar Leonidas (es_PE)
Merino Martinez, Marcelo Edmundo (es_PE)
Galicia Guarniz, William Conrad (es_PE)
http://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada asociativa



This item is licensed under a Creative Commons License Creative Commons