Abstract: Esta tesis se ha ejecutada con el fin de comparar el uso de muros estructurales de concreto, que es el que contempla la norma peruana E0.30: Diseño Sismorresistente, con respecto a los disipadores sísmico Shear Link Bozzo, contemplados en la norma internacional ASCE 7-16. Se tomó la estructura con muros estructurales, como la estructura original debido a la cantidad de pisos, por lo que sin lugar a duda era necesario reforzar. Se efectuó un AENL por el método de espectro de capacidad, en ambos sistemas, con el fin de identificar curvas de capacidad y sus puntos de desempeño. El contraste de estas posibilita corroborar las indudables diferencias entre ambos sistemas, advirtiendo la magnitud en la que se logra acentuar la resistencia debido a las derivas. De la norma E0.30: Diseño Sismorresistente, se obtienen los criterios necesarios para precisar el espectro de diseño y poder realizar los análisis lineales básicos para el diseño de la estructura que nos funcionarían para concretar el análisis estático no lineal y con esto identificar y señalar los puntos de desempeño de las estructuras, esto representa el máximo desplazamiento al que las estructuras están sometidas si se diera lugar el sismo del diseño, razón por la cual estas se contrastan, junto con la capacidad estructural. El análisis no lineal, Pushover, demandó obtener la distribución de fuerzas laterales, calculadas con ayuda del programa Etabs y Excel, y permite evidenciar la secuencia en la que se forman las rótulas plásticas en las vigas y columnas según intensifica la cortante basal, por lo cual se concretó un cotejo del estado estructural en el punto de desempeño, dándonos un parámetro del que nos logramos orientar para dictaminar cual reforzamiento es apropiado. Nuestros resultados finales son la comparativa del nivel de desempeño, derivas inelásticas y cortantes basales para cada sistema de reforzamiento estructural

This thesis has been executed in order to compare the use of structural concrete walls, which is the one contemplated by the Peruvian standard E0.30: Seismicresistant Design, with respect to the Shear Link Bozzo seismic dissipators, contemplated in the international standard ASCE 7 -16. The structure with structural walls was taken as the original structure due to the number of floors, so without a doubt it was necessary to reinforce. A non-linear static analysis was carried out by the capacity spectrum method, in both systems, in order to identify their capacity curves and their performance points. The contrast of the capacity curves makes it possible to corroborate the undoubted differences between both systems, noting the magnitude in which resistance due to drifts is accentuated. From the E0.30 standard: Earthquake Resistant Design, the necessary criteria are obtained to specify the design spectrum and to be able to carry out the basic linear analyzes for the design of the structure that would work for us to specify the non-linear static analysis and with this identify and indicate the performance points of the structures, this represents the maximum displacement to which the structures are subjected if the design earthquake were to occur, which is why these are contrasted, together with the structural capacity. The nonlinear analysis, Pushover, demanded to obtain the distribution of lateral forces, calculated with the help of the Etabs and Excel program, and allows to demonstrate the sequence in which the plastic hinges are formed in the beams and columns as the basal shear intensifies, therefore which made a comparison of the structural state at the performance point, giving us a parameter from which we could guide ourselves to determine which reinforcement is appropriate. Our final results are the comparison of the performance level, inelastic drifts and basal shear for each structural reinforcement system
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Privada Antenor Orrego. Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Alanoca Quenta, Angel; Cancino Rodas, César; Vertiz Malabrigo, Manuel
Register date: 4-Mar-2021



This item is licensed under a Creative Commons License Creative Commons