Buscar en Google Scholar
Título: Diseño estructural de un edificio de diez niveles para oficinas, usando muros estructurales en el Distrito de Pimentel, Provincia de Chiclayo
Asesor(es): Merino Martinez, Marcelo Edmundo
Campo OCDE: https://purl.org/pe-repo/ocde/ford#2.01.00
Fecha de publicación: 2024
Institución: Universidad Privada Antenor Orrego
Resumen: La tesis tiene por objetivo realizar el análisis y diseño estructural de un edificio de Diez niveles más un semisótano considerando el sistema estructural de muros de concreto armado, teniendo en cuenta que el edificio a proyectar se encuentra en el distrito de Pimentel, Chiclayo, por su ubicación se encuentra en una zona de alta actividad sísmica. El edificio administrativo a diseñar forma parte de la infraestructura que se está dotando a la ciudad para las principales actividades económicas y educativas. Para el análisis estructural del edificio se utilizó el software Etabs como software principal de análisis, en la cual se realizó el modelo matemático, análisis estático, análisis dinámico, y análisis modal, con la finalidad de asegurar que los resultados que arrojan los softwares de análisis se han creado hojas de cálculo puesto que los programas son herramientas computacionales que ayudan a mejorar la productividad dentro de un proyecto. Se realizó el diseño de elementos estructurales como las vigas, a flexión y por capacidad; las columnas, se diseñaron a flexo compresión y capacidad; las losas aligeradas, se modelaron en el software Safe y se realizó su posterior diseño en hojas de cálculo, se verifico las deflexiones y el agrietamiento en losas según se menciona en la NTP. E060; las losas macizas, se diseñaron a flexión y se verifico el cortante. En el diseño de muros estructurales se ha tenido que emplear el software Etabs para encontrar las solicitaciones, se usó el programa Sap 2000 para encontrar la profundidad del eje neutro, hojas de cálculo para el diseño de muros a flexo compresión, y a cortante por capacidad, se diseñaron los elementos de borde. Por último, se diseñó de la cimentación considerando la normatividad vigente, escaleras y muros de sótano, después de ello se realizó la ingeniería de detalle de todos los elementos estructurales, el detalle de acero en cada viga, columnas y muros de concreto armado, en el caso de muros se realizó la comparación de la NTP E.060 y el ACI 318.19. en donde podemos apreciar que tenemos que mejorar los criterios para el confinamiento de elementos de borde.

The objective of the thesis is to carry out the analysis and structural design of a ten-story building plus a semi-basement considering the structural system of reinforced concrete walls, taking into account that the building to be designed is located in the district of Pimentel, Chiclayo, for its Location is in an area of high seismic activity. The administrative building to be designed is part of the infrastructure that is being provided to the city for the main economic and educational activities. For the structural analysis of the building, the Etabs software was used as the main analysis software, in which the mathematical model, static analysis, dynamic analysis, and modal analysis were carried out, in order to ensure that the results provided by the analysis software Spreadsheets have been created since the programs are computational tools that help improve productivity within a project. The design of structural elements such as beams was carried out, for bending and capacity; The columns were designed for flexo-compression and capacity; The lightened slabs were modeled in the Safe software and their subsequent design was carried out in spreadsheets, the deflections and cracking in the slabs were verified as mentioned in the NTP. E060; The solid slabs were designed in bending and the shear was verified. In the design of structural walls, the Etabs software had to be used to find the stresses, the Sap 2000 program was used to find the depth of the neutral axis, spreadsheets for the design of flexo-compression walls, and capacity shear, for example. Lastly, the border elements were designed. Finally, the foundation was designed considering the current regulations, stairs and basement walls, after which the detailed engineering of all the structural elements was carried out, the steel detail in each beam, columns and reinforced concrete walls, in the case of walls, a comparison was made between NTP E.060 and ACI 318.19, where we can see that we have to improve the criteria for the confinement of edge elements
Disciplina académico-profesional: Ingenieria Civil
Institución que otorga el grado o título: Universidad Privada Antenor Orrego. Facultad de Ingenieria
Grado o título: Ingeniero Civil
Jurado: Lopez Carranza, Atilio Ruben; Moran Guerrero, Victor Manuel; Galicia Guarniz, William Conrad
Fecha de registro: 9-ago-2024



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons