Bibliographic citations
Molina, R., (2019). Análisis de la resistencia unitaria lateral última de micropilotes inyectados en arcillas saturadas de Cusco a través de pruebas de carga [Tesis, Universidad Peruana de Ciencias Aplicadas (UPC)]. http://hdl.handle.net/10757/626473
Molina, R., Análisis de la resistencia unitaria lateral última de micropilotes inyectados en arcillas saturadas de Cusco a través de pruebas de carga [Tesis]. PE: Universidad Peruana de Ciencias Aplicadas (UPC); 2019. http://hdl.handle.net/10757/626473
@misc{renati/369069,
title = "Análisis de la resistencia unitaria lateral última de micropilotes inyectados en arcillas saturadas de Cusco a través de pruebas de carga",
author = "Molina Lovatón, Rodrigo",
publisher = "Universidad Peruana de Ciencias Aplicadas (UPC)",
year = "2019"
}
The objective of this research is to determine the ultimate lateral unitary resistance of the bulb of micropiles executed by repetitive injection (RI) based on load tests in saturated clay soils on the district of San Sebastian - Cusco, 2016. The study was prepared based on the information provided by companies specialized in soil studies, micropiles and load testing. Eight of fourteen load tests performed in total were analyzed, because they reached failure. In all tests, a manometer was used that measured the force exerted by four hydraulic jacks, as indicated by ASTM D1143. To obtain the last lateral unitary resistance of the bulb (qs), first, the last load was determined, then, at this value, the contribution of lateral load in the non-injected length was subtracted, and that result was divided between the lateral area of contact between the bulb and the surrounding soil. It was determined that the micropiles reached final loads from 39.40 to 101.30 tons, in addition, the contact areas between the bulb and the soil were estimated between 16.51 and 38.46 m2, from this, it was determined that the ultimate lateral unit resistances vary between 1.29 and 3.45 tons per square meter. The purpose of this research is to contribute to the best estimate of the ultimate lateral unitary resistance of the RI-type micropile bulb in saturated clays with SPT number between 10 and 32.
This item is licensed under a Creative Commons License