Título: Evaluación de juntas sísmicas en edificios multifamiliares de 5 niveles mediante simulación de sismo con elementos GAP
Otros títulos: Impact modeling of buildings subjected to earthquakes
Campo OCDE: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Fecha de publicación: 13-nov-2024
Institución: Universidad Peruana de Ciencias Aplicadas (UPC)
Resumen: Crecimos conscientes respecto a la ubicación geográfica del Perú, situada en el denominado “cinturón de fuego del pacífico”, una de las zonas con mayor presencia de actividad sísmica del planeta; lo cual a menor o mayor escala nos ha generado una conciencia antisísmica, ligada a respetar normativas, procesos e incentivar investigaciones en beneficio de mitigar los efectos de los sismos. En ese sentido, proponemos ahondar en el diseño y verificación de juntas sísmicas en edificios de 5 pisos, mediante el modelamiento en software ETABS añadiendo elementos GAP para simular el efecto de la junta. Por ello; podremos identificar durante la etapa de interpretación de resultados, si el diseño de junta propuesto es funcional relacionado al número de pisos de las edificaciones, identificado mediante el simulador de sismos del programa ETABS. Concluyendo, que la junta propuesta evita el golpeteo entre edificaciones a causa del sismo, lo cual nos permite validar un correcto diseño de junta.

We grew aware of the geographical location of Peru, located in the so-called “Pacific Ring of Fire”, one of the areas with the greatest presence of seismic activity on the planet, which on a smaller or larger scale has generated in us an anti-seismic awareness, linked to respecting regulations, processes and encouraging research to benefit mitigating the effects of earthquakes. In this sense, we propose to delve into the design and verification of seismic joints in buildings of 5 floors, through modeling in ETABS software adding GAP elements to simulate the effect of the joint. Therefore; We will be able to identify during the results interpretation stage, if the proposed joint design is functional related to the number of floors of the buildings, identified through the earthquake simulator of the ETABS program. Concluding, that the proposed joint avoids the knocking between buildings due to the earthquake, which allows us to validate a correct joint design.
Enlace al repositorio: http://hdl.handle.net/10757/683037
Disciplina académico-profesional: Ingeniería Civil
Institución que otorga el grado o título: Universidad Peruana de Ciencias Aplicadas (UPC). División de Estudios Profesionales para Ejecutivos (EPE)
Grado o título: Ingeniero Civil
Jurado: Serrano Lazo, Malena Alessandra; Soto Oblea, Edward Jonathan
Fecha de registro: 12-dic-2024



Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons