Title: Evaluación estructural de una vivienda unifamiliar de albañilería confinada y su proyección a cuatro niveles en San Juan de Miraflores
Other Titles: Structural evaluation of a confined masonry single-family home and its projection on four levels in San Juan de Miraflores
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Issue Date: 13-Nov-2024
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: El propósito de este trabajo de investigación es realizar una ampliación a una vivienda existente de dos a cuatro niveles y verificar si esta cumple con las condiciones tanto de diseño sismorresistente y de albañilería confinada. Esto fue modelado en el software ETABS para así poder analizar los desplazamientos ante un sismo y verificar si cumple con lo establecido en la Norma Técnica Peruana E.030. La vivienda se construyó en un terreno de 160 metros cuadrados, consta de dos niveles con una altura de 2.40 por piso. Las derivas de entrepiso se obtuvieron mediante un análisis modal espectral, respetando lo establecido en la Norma sismorresistente E.030. A través del software ETABS fue posible realizar el análisis y obtener los resultados tanto de la vivienda existente como su proyección ante un sismo. Además, se realizó la verificación de fisuramiento de los muros portantes y el diseño de columneta y viga solera siguiendo los criterios de la norma peruana E.070. En la proyección de la vivienda se verificó que las derivas cumplen con lo establecido en la norma ya que son menores que 0.005 (según norma E.030). Además, según el diseño de columneta y viga solera, es factible la proyección porque las dimensiones de esos elementos de confinamiento cumplen con lo requerido en la norma E.070.

The purpose of this research work is to carry out an extension to an existing two- to four-story home and verify if it meets the conditions of both earthquake-resistant design and confined masonry. This was modeled in the ETABS software in order to analyze the displacements in the event of an earthquake and verify if it complies with the provisions of the Peruvian Technical Standard E.030. The house was built on a 160 square meter plot of land, it consists of two levels with a height of 2.40 per floor. The mezzanine drifts were obtained through a modal spectral analysis, respecting the provisions of the E.030 earthquake-resistant standard. Through the ETABS software it was possible to carry out the analysis and obtain the results of both the existing home and its projection in the event of an earthquake. In addition, the cracking verification of the load-bearing walls and the design of the column and base beam were carried out following the criteria of the Peruvian standard E.070. In the projection of the home, it was verified that the drifts comply with what is established in the standard since they are less than 0.005 (according to standard E.030). Furthermore, depending on the design of the column and base beam, the projection is feasible because the dimensions of these confinement elements comply with the requirements of standard E.070.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Serrano Lazo, Malena Alessandra; Moreno Sanchez, Javier Daniel
Register date: 12-Dec-2024