Look-up in Google Scholar
Title: Evaluación experimental de los coeficientes de gastos en vertederos de pared delgada tipo: semicircular, parabólico, trapezoidal y sutro en canales rectangulares
Advisor(s): De La Torre Ostos, Juan Miguel
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 23-Feb-2024
Institution: Universidad Privada del Norte
Abstract: La presente investigación tiene como objetivo realizar una evaluación experimental de los coeficientes de gastos utilizados en vertederos de pared delgada, semicircular, parabólico, trapezoidal y sutro para realizar aforos en canales rectangulares, el tipo de investigación fue cuantitativa, aplicada, descriptiva y no experimental. Asimismo, la población son los vertederos investigados y la muestra son los vertederos evaluados en el canal rectangular; semicircular, parabólico, trapezoidal y sutro. Con el uso de los laboratorios de la UPN Sede Los Olivos se pudo hallar los coeficientes de gasto de cada diseño de vertedero tanto de manera física como de manera matemática con ayuda del vertedero triangular calibrado de 53° 7’, los caudales a utilizar fueron de 3.32 l/s, 4.10 l/s, 5.38 l/s, 6.25 l/s, 7.54 l/s y 8.21 l/s; a cada formula general de los vertederos evaluados en el canal rectangular se le añadió un coeficiente de gasto donde se hace el arreglo manual, oscilando a un valor entre 0 a 1 posteriormente en cada curva de calibración se determinó que, a mayor caudal, mayor será la altura del agua. Y como conclusión final se logró la evaluación experimental de los coeficientes de gastos utilizados en vertederos de pared delgada, además de graficar sus curvas de calibración y verificar sus fórmulas tanto de manera física y manual.

The objective of this research is to carry out an experimental evaluation of the cost coefficients used in thin-walled, semicircular, parabolic, trapezoidal and sutro weirs to carry out gauging in rectangular channels. The type of research was quantitative, applied, descriptive and non-experimental. Likewise, the population is the investigated landfills and the sample is the landfills evaluated in the rectangular channel; semicircular, parabolic, trapezoidal and sutro. With the use of the laboratories of the UPN Los Olivos Headquarters, the flow coefficients of each spillway design could be found both physically and mathematically with the help of the calibrated triangular spillway of 53° 7', the flows to be used were 3.32 l/s, 4.10 l/s, 5.38 l/s, 6.25 l/s, 7.54 l/s and 8.21 l/s; To each general formula of the weirs evaluated in the rectangular channel, a cost coefficient was added where the manual arrangement is made, oscillating at a value between 0 to 1. Subsequently, in each calibration curve, it was determined that, the greater the flow, the greater the the height of the water. And as a final conclusion, the experimental evaluation of the expense coefficients used in thin-walled landfills was achieved, in addition to graphing their calibration curves and verifying their formulas both physically and manually.
Note: San Juan de Lurigancho
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Privada del Norte. Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Campos Vasquez, Neicer; Neyra Torres, Jose L.; Manturano Chipana, Ruben K.
Register date: 6-Jun-2024; 6-Jun-2024



This item is licensed under a Creative Commons License Creative Commons