Look-up in Google Scholar
Title: Evaluación del desempeño sísmico de los planos modificados del Hospital Luis Negreiros Vega - Callao, aplicando disipadores de fluido viscoso en disposición diagonal y Chevron
Advisor(s): Moreno Sánchez, Javier
OCDE field: https://purl.org/pe-repo/ocde/ford#2.00.00; https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 1-Nov-2023
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: La investigación se enfoca en la evaluación sísmica del Pabellón B del Hospital Luis Negreiros Vega. El caso de estudio fue configurado con disipadores de fluido viscoso en configuración chevrón y configuración diagonal. Se evaluaron los parámetros sísmicos más representativos. Entre ellos, las distorsiones de entre piso, las fuerzas disipadoras, el coeficiente de amortiguamiento de diseño y principalmente las irregularidades torsionales que tienen un impacto significativo en las edificaciones. Los disipadores se implementaron a través del criterio de los desplazamientos máximos. Es decir, se ubicaron donde los desplazamientos de los nodos fueron más elevados. Para la modelación se utilizaron disipadores de fluido viscoso no lineales con exponente de velocidad de diseño (𝞪=0.5). Se desarrolló un modelo matemático con el Software ETABS 18. Se utilizó la metodología planteada en los códigos extranjeros: FEMA, y HAZUS. Del diseño se calculó el coeficiente de amortiguamiento óptimo de la estructura para ambas direcciones X, Y. El análisis de la edificación se desarrolló con valores de entrada de “tiempo-historia”, definidos por el RNE, por tres (03) grupos de acelerogramas horizontales, los cuales fueron escalados a nuestro espectro elástico de diseño con el Software SEISMOMATCH. Del análisis de los resultados, se determinó que: a nivel de distorsiones los disipadores en configuración chevrón son ligeramente más eficientes que los disipadores en configuración diagonal a nivel de análisis por pórtico. Por otro lado, se determinó que los disipadores de fluido viscoso, cuando son colocados en los nodos con mayor desplazamiento de la edificación, reducen significativamente las irregularidades torsionales (𝜟max/𝜟prom) de la estructura.

The research focuses on the seismic evaluation of Pavilion B of the Luis Negreiros Vega Hospital. The case study was configured with viscous fluid heatsinks in chevron configuration and diagonal configuration. The most representative seismic parameters were evaluated. Among them, inter-story distortions, dissipative forces, the design damping coefficient and mainly torsional irregularities that have a significant impact on buildings. The heatsinks were implemented through the criterion of maximum displacements. That is, they were located where the node displacements were highest. Nonlinear viscous fluid heatsinks with design velocity exponent (𝞪=0.5) were used for modeling. A mathematical model was developed with the ETABS 18 Software. The methodology proposed in foreign codes was used: FEMA and HAZUS. From the design, the optimal damping coefficient of the structure was calculated for both X and Y directions. The analysis of the building was developed with “time-history” input values, defined by the RNE, by three (03) groups of accelerograms horizontals, which were scaled to our elastic design spectrum with SEISMOMATCH Software. From the analysis of the results, it was determined that: at the level of distortions, the heatsinks in chevron configuration are slightly more efficient than the heatsinks in diagonal configuration at the level of analysis per gantry. On the other hand, it was determined that the viscous fluid dissipators, when placed in the nodes with the greatest displacement of the building, significantly reduce the torsional irregularities (𝜟max/𝜟prom) of the structure.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Serrano Lazo, Malena; Anza Moreau, César; Soto Oblea, Edward Jonathan
Register date: 15-Feb-2024; 15-Feb-2024



This item is licensed under a Creative Commons License Creative Commons