Look-up in Google Scholar
Title: Evaluación numérica del comportamiento sísmico de un muro Inca del Templo del Coricancha en el Cusco con encajes y sin encajes
Other Titles: Numerical evaluation of the seismic behavior of an Inca wall with and without lace from the Coricancha Temple in Cusco
Advisor(s): Lipa Cusi, Leonel
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Issue Date: 14-Nov-2023
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: Los muros incaicos posiblemente han sufrido distintos tipos de daño a través del tiempo causados por la naturaleza, una de estas causas son los eventos sísmicos. El silencio sísmico que vive la región del cusco es la principal amenaza para las distintas estructuras que aún sobreviven desde su construcción. Esto es debido a que alrededor de la región del cusco se ubican fallas activas como las de Qoricocha y Tambomachay, donde se registró el sismo con mayor magnitud de los últimos años. En la actualidad, existen muy pocos estudios a estos tipos de estructuras de junta seca que ayuden a implementar medidas de conservación y preservación para que puedan ser apreciadas por generaciones futuras. Por tal motivo, este estudio de investigación tiene como finalidad contribuir con la evaluación numérica del comportamiento sísmico de un muro Inca con encajes y sin encajes del Templo del Coricancha en el Cusco. Para realizar este estudio, primero se escogió un muro Inca del Templo del Coricancha, luego se designó dos casos para el muro, con encaje y sin encaje. De esta manera, se dibujó ambos casos en AutoCAD y se exportó al software Abaqus. Luego, se realizó el modelado del muro evaluado con el sismo de Paruro a diferentes escalas. Como resultado se obtuvo que, para un PGA de 0.1g el máximo desplazamiento relativo fue de 0.079m en el muro con encaje y 0.279m en el muro sin encaje. Mientras que, para un PGA de 0.2g el máximo desplazamiento relativo fue de 0.441m y 0.245m respectivamente. Por otro lado, cuando el PGA fue de 0.3g se obtuvo un colapso parcial de 29.41% en el muro con encaje y un colapso prácticamente total de 84.21% en el muro sin encaje. Por último, cuando el PGA fue de 0.4g se obtuvo un colapso de 41.18% para el muro con encaje, mientras que, para el caso del muro sin encaje, no se evaluó ya que persiste el colapso total de la estructura desde el PGA de 0.3g.

The Inca walls have possibly suffered different types of damage over time caused by nature, one of these causes is seismic events. The seismic silence that the Cusco region is experiencing is the main threat to the different structures that still survive since their construction. This is because active faults such as Qoricocha and Tambomachay are located around the Cusco region, where the largest earthquake in recent years was recorded. Currently, there are very few studies on these types of dry joint structures that help implement conservation and preservation measures so that they can be appreciated by future generations. For this reason, this research study aims to contribute to the numerical evaluation of the seismic behavior of an Inca wall with and without lace from the Coricancha Temple in Cusco. To carry out this study, first an Inca wall from the Coricancha Temple was chosen, then two cases were designated for the wall, with lace and without lace. In this way, both cases were drawn in AutoCAD and exported to Abaqus software. Then, the modeling of the wall evaluated with the Paruro earthquake was carried out at different scales. As a result, it was obtained that, for a PGA of 0.1g, the maximum relative displacement was 0.079m in the wall with socket and 0.279m in the wall without socket. While, for a PGA of 0.2g the maximum relative displacement was 0.441m and 0.245m respectively. On the other hand, when the PGA was 0.3g, a partial collapse of 29.41% was obtained in the wall with socket and a practically total collapse of 84.21% in the wall without socket. Finally, when the PGA was 0.4g, a collapse of 41.18% was obtained for the wall with socket, while, in the case of the wall without socket, it was not evaluated since the total collapse of the structure persists from the PGA of 0.3g.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Peña Torres, Pablo Jhoel; Huerta Campos Carlos Alberto
Register date: 29-Dec-2023; 29-Dec-2023



This item is licensed under a Creative Commons License Creative Commons