Title: Reforzamiento estructural para una mejor resistencia a cargas sísmicas del edificio Trecca según la norma E030
Other Titles: Structural reinforcement for better resistance to seismic loads of the trecca building according to standard E030
Advisor(s): Córdova Shedan, Romel
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01; https://purl.org/pe-repo/ocde/ford#2.00.00
Issue Date: 14-Nov-2023
Institution: Universidad Peruana de Ciencias Aplicadas (UPC)
Abstract: La presente investigación se realizó con el objetivo de proponer un sistema de reforzamiento para la torre Trecca. El emblemático edificio peruano quedó paralizado y permanece abandonado debido a sus irregularidades en el diseño. Fue diseñado antes de la implementación de la primera versión de la normativa E030 y construido durante las diversas actualizaciones de dicha norma, por ello la estructura obtuvo posteriormente su paralización y parcial abandono. La investigación llevo a cabo el análisis estático y dinámico de la edificación en dos puntos, el primero con el modelo original y el segundo con el modelo ya reforzado. Estos análisis permiten definir si cumplieron con los límites permisibles de distorsión, fuerza cortante y chequeo de las derivas. Debiendo ser este último ser inferior al 1% de la altura del nivel. Como herramienta de uso se utilizó el programa Etabs 2020 para el análisis de datos y el programa Revit 2021 para el diseño de la estructura en su versión actual y reforzada. En los resultados obtenidos se puede observar como la versión actual de la estructura no cumple con los límites establecidos en la norma E030 siendo que en la distorsión de desplazamientos laterales a partir del nivel 4 al 22 estos superan el 0.007 de distorsión para estructuras de concreto armado, a diferencia del diseño reforzado cuya distorsión a lo largo de toda la sección no excede el límite admisible. Finalmente, al realizar el chequeo de las derivas, el modelo actual en el eje X supera el límite del 1%, llegando a un 1,68% en su punto máximo, contrario a los resultados del modelo reforzado, que en su máximo alcanza un 0,52%.

The investigation was carried out with the objective of proposing a reinforcement system for the Trecca tower. The emblematic Peruvian building came to a standstill and remains abandoned due to its design irregularities. It was designed prior to the implementation of the first version of the E030 regulations and was constructed during the various updates to that norm. The research carried out an in-depth analysis of the static and dynamic of the building at two points, the first with the original model and the second with the already reinforced model. These analyses allow to define if they met the permissible limits of distortion, shear force and drift check. The latter having to be less than 1% of the height of the level. As a tool of use, the Etabs 2020 program was used for data analysis and the Revit 2021 program was used for the design of the structure in its current and reinforced version. In the results obtained, it can be observed how the current version of the structure does not comply with the limits established in the norm E030, and that in the distortion of lateral displacements from level 4 to 22 these exceed the 0.007 permissible distortion for reinforced concrete structures, contrary to the reinforced design whose distortion along the entire section does not exceed the admissible limit. Finally, when conducting the drift check, the current model in the X-axis exceeds the 1% limit, reaching 1.68% at the most critical point, contrary to the results of the reinforced model, which at its maximum reaches a 0.52%
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Peruana de Ciencias Aplicadas (UPC). Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Soto Oblea, Edward Jonathan; Anza Moreau, Cesar Augusto
Register date: 27-Dec-2023; 27-Dec-2023