Meliton, J., & Miyashiro, R. M. (2022). Estudio comparativo de los tratamientos de electrocoagulación y coagulación/ floculación para la remoción de contaminantes de aguas residuales del camal Conchucos, Lima, 2021 [Tesis de licenciatura, Universidad Privada del Norte]. Repositorio de la Universidad Privada del Norte. https://hdl.handle.net/11537/31248 (es_PE)
628.32 MELI/E 2022 (es_PE)
https://hdl.handle.net/11537/31248
Los Olivos (sede)
En este trabajo se comparó los tratamientos de coagulación-floculación y electrocoagulación en la remoción de contaminantes de aguas residuales del camal Conchucos, Lima. Para el tratamiento de coagulación-floculación se trabajó con 4 variables independientes con sus respectivos rangos de experimentación, dosis de coagulante (600 1000 mg/L), dosis de floculante (4-8 mg/L), velocidad de agitación rápida (250-350 rpm), velocidad de agitación lenta (80-100 rpm), para la electrocoagulación los parámetros de velocidad de agitación (250-350 rpm) y tiempo de agitación (15-30 rpm). Se usó el método de diseño central compuesto (DCC) optimizando mediante superficie de respuesta (RSM) como método experimental para la reducción de contaminantes en función de la demanda química de oxígeno (%DQO), se usó un equipo de prueba de jarras para la coagulación floculación y un agitador de un litro con electrodos de placa de aluminio a 30 V. Los resultados muestran que la coagulación/floculación y electrocoagulación presentaron modelos estadísticos con valores F de 5.33, 20.30, significancias p < 0,05, con ajustes de R2 de 0,6179, y 0,7571 para un arreglo óptimo con predicciones de reducción de %DQO, respectivamente. El tratamiento de electrocoagulación presento una reducción de 75.43% similar al modelo predecido, de los 2 tratamientos comparados la electroremediación está por debajo de los valores máximos admisibles (VMA) en DQO, DBO y Aceites y Grasas cumpliendo los parámetros necesarios para el vertimiento a la red de alcantarillado. (es_PE)
In this work, the coagulation-flocculation and electrocoagulation treatments were compared in the removal of pollutants from wastewater from the Conchucos slaughterhouse, Lima. For the coagulation-flocculation treatment, we worked with 4 independent variables with their respective experimental ranges, coagulant dose (600-1000 mg / L), flocculant dose (4-8 mg / L), fast stirring speed (250-350 rpm) , slow stirring speed (80-100 rpm), for electrocoagulation the parameters of stirring speed (250-350 rpm) and stirring time (15-30 rpm). The central compound design method (DCC) optimizing by response surface (RSM) was used as an experimental method for the reduction of pollutants as a function of chemical oxygen demand (% COD), a jar test equipment was used for the coagulation-flocculation and a one-liter shaker with aluminum plate electrodes at 30 V. The results show that coagulation / flocculation and electrocoagulation presented statistical models with F values of 5.33, 20.30, significance p<0.05, with adjustments of R2 of 0.6179, and 0.7571 for an optimal arrangement with % COD reduction predictions, respectively. The electrocoagulation treatment presented a reduction of 75.43% similar to the predicted model, of the 2 treatments compared, the electroremediation is below the maximum admissible values (VMA) in COD, BOD and Oils and Fats, complying with the necessary parameters for the discharge to the sewerage system. (es_PE)
Tesis (es_PE)
application/pdf (es_PE)
application/msword (es_PE)
spa (es_PE)
Universidad Privada del Norte (es_PE)
Atribución-NoComercial-CompartirIgual 3.0 Estados Unidos de América
info:eu-repo/semantics/openAccess (es_PE)
https://creativecommons.org/licenses/by-nc-sa/3.0/us/
Repositorio Institucional - UPN (es_PE)
Universidad Privada del Norte (es_PE)
Floculación (es_PE)
Aguas residuales (es_PE)
Contaminación (es_PE)
Ganadería (es_PE)
Matadero (es_PE)
Coagulación (es_PE)
Estudio comparativo de los tratamientos de electrocoagulación y coagulación/ floculación para la remoción de contaminantes de aguas residuales del camal Conchucos, Lima, 2021 (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Privada del Norte. Facultad de Ingeniería (es_PE)
Ingeniería Ambiental (es_PE)
Ingeniero (es_PE)
Ingeniero Ambiental (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.07.00 (es_PE)
http://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
45997406
https://orcid.org/0000-0002-4038-7591 (es_PE)
73987894
72185906
521066 (es_PE)
Torres Joaquin, Haniel Josue
Cateriano Calderón, Margarita del Carmen
Alva Mendoza, Denisse Milagros
http://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada societaria



This item is licensed under a Creative Commons License Creative Commons