Title: Evaluación del desempeño sísmico con disipadores a fricción en dos edificios bajos en el centro poblado El Milagro, Trujillo 2020
Advisor(s): Díaz García, Gonzalo Hugo
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 17-Dec-2019
Institution: Universidad Privada del Norte
Abstract: El presente trabajo de investigación se desarrolló en la ciudad de Trujillo, En el centro poblado El Milagro, teniendo como principal objetivo determinar y evaluar el desempeño sísmico con disipadores a fricción en edificios bajos ante un sismo severo, para cumplir el objetivo en primer lugar se identificó dos estructuras bajas con el cual se hizo el modelamiento estructural original de las dos edificaciones, luego se determinó el análisis estructural sísmico (estático, dinámico y modal) según nuestra norma peruana E.0.302018,en el cual también se hizo un análisis tiempo historia no lineal para obtener el sismo de diseño en el cual se pudo evaluar las edificaciones ante un sismo severo por el cual se diseñó el disipador a fricción para ambas edificaciones según la característica de su estructura y arquitectura y finalmente por medio del análisis tiempo historia no lineal con disipadores a fricción se determinó el desempeño sísmico ante un sismo severo. Los resultados de la presente investigación nos ofrecen la posibilidad de diseñar estructuras bajas con disipadores a fricción que puedan soportar sismos severos de gran magnitud, debido a que la ciudad de Trujillo está situada en zona sísmica, esta tesis ayuda con el objetivo de cuidar la vida de las personas y disminuir las pérdidas económicas productos de las pérdidas de infraestructuras. Entre los resultados más importantes que se obtuvieron tenemos que las derivas en entrepiso de ambas edificaciones cumplen con el mínimo de deriva que es de 0.007 m que nos da la norma de sismo E.030-2018.Entre el análisis de ambas estructuras se obtuvo la máxima deriva de entrepiso que es de 0.0065 m entre ambos ejes, por lo cual se demuestra que el desempeño sísmico de las estructuras con disipadores de fricción es óptimo ante un sismo severo. Entre las conclusiones más importantes tenemos que el porcentaje de reducción sísmica de las dos estructuras con y sin disipadores a fricción tienen un valor máximo de 92.09% de reducción entre las dos estructuras.

The present work of investigation was developed in the city of Trujillo, populated center El Milagro, having as main objective to determine and to evaluate the seismic performance with friction dissipaters in low buildings before a severe earthquake, to fulfill the objective in the first place two low structures were identified with which the original structural modeling of the two buildings was made, then the seismic structural analysis was determined (static, dynamic and modal) according to our Peruvian norm E.0..30-2018, in which a non-linear time history analysis was also made to obtain the design earthquake in which the buildings could be evaluated before a severe earthquake by which the friction dissipater was designed for both buildings according to the characteristic of their structure and architecture and finally by means of the non-linear time history analysis with friction dissipaters the seismic performance before a severe earthquake was determined.The importance of the present investigation gives us the possibility of establishing low structures with friction dissipaters that can support different seismic levels but the most important one before a severe earthquake of great magnitude, knowing that the city of Trujillo is located in seismic zone, helping in this way with the objective of taking care of the life of the people and diminishing the economic losses products of the losses of infrastructures. Among the most important results that were obtained were the drifts in mezzanine of both buildings meet the minimum drift that is 0.007 m that gives us the earthquake standard E.030-2018, between the analysis of both structures was obtained the maximum drift of mezzanine that is 0.0065 m between both axes, so we can say that the seismic performance of the structures with friction dissipaters is optimal to a severe earthquake. Among the most important conclusions is the percentage of seismic reduction of the two structures with and without friction dissipaters obtaining a maximum of 92.09% of maximum reduction between the two structures and we can also say that friction dissipaters are more efficient than other types of dissipaters.
Note: Trujillo San Isidro
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Privada del Norte. Facultad de Ingeniería
Grade or title: Ingeniero Civil
Register date: 5-Feb-2020; 5-Feb-2020