Title: Principales elementos ambientales que degradan el concreto armado en columnas del Centro Educativo Inicial N° 124, Lambayeque, 2016
Advisor(s): Obando Peralta, Ena Cecilia
OCDE field: https://purl.org/pe-repo/ocde/ford#2.07.00
Issue Date: 14-Jun-2019
Institution: Universidad Privada del Norte
Abstract: La presente investigación, tuvo como objetivo describir los principales elementos ambientales que degradan el concreto armado en columnas del centro educativo inicial N° 124, Lambayeque; por lo que se identificó el valor del dióxido de carbono (CO2) atmosférico en el lugar de estudio y la descripción de las variables meteorológicas más relevantes, así como la aplicación de normas estandarizadas UNE EN – 14630:2006, UNE 112011, NTP 339.059.2011, NTP 339.034:2013, que a través de ensayos en núcleos de concreto permite identificar la presencia del CO2 y resistencia a la compresión axial. De los resultados se observaron que los núcleos de concreto extraídos de las columnas, se encuentran afectadas por el CO2 atmosférico, aunado a las variables ambientales del lugar que brindan las condiciones para su degradación. Concluyendo que en 10 años de construcción de este centro educativo, las columnas de concreto armado se encuentran afectadas por carbonatación, producto de la perdida de alcalinidad y además de la disminución de la resistencia a la compresión axial, conllevándolo a una baja durabilidad en el tiempo de la estructura.

The objective of this research was to describe the main environmental elements that degrade the reinforced concrete in columns of the initial educational center N° 124, Lambayeque; therefore, the value of atmospheric carbon dioxide (CO ) at the study site and the description of the most relevant meteorological variables was identified, as well as the application of standardized standards UNE EN - 14630: 2006, UNE 112011, NTP 339.059. 2011, NTP 339.034: 2013, which through tests on concrete cores allows to identify the presence of CO 2 and resistance to axial compression. From the results it was observed that the concrete cores extracted from the columns are affected by the atmospheric CO 2 2 , together with the environmental variables of the place that provide the conditions for their degradation. Concluding that in 10 years of construction of this educational center, the columns of reinforced concrete are affected by carbonation, product of the loss of alkalinity and in addition to the reduction of the resistance to axial compression, leading to a low durability over time of the structure.
Note: Cajamarca
Discipline: Maestría en Gestión Ambiental y Resolución de Conflictos
Grade or title grantor: Universidad Privada del Norte. Escuela de Posgrado y Estudios Continuos
Grade or title: Maestro en Gestión Ambiental y Resolución de Conflictos
Register date: 5-Jul-2019; 5-Jul-2019



This item is licensed under a Creative Commons License Creative Commons