Look-up in Google Scholar
Title: Análisis de la resistencia a la compresión del concreto F’c=210 kg/cm2 con adición de vidrio reciclado molido
Advisor(s): Pinchi Vasquez, Eduardo
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 2019
Institution: Universidad Nacional de San Martín. Fondo Editorial
Abstract: La presente investigación tuvo como objetivo principal analizar la resistencia a la compresión del concreto F’c=210 Kg/cm2 con adición de vidrio reciclado molido, mediante el reemplazo parcial en peso del agregado fino en porcentajes del 15%, 20% y 25%, con la finalidad de establecer una comparación entre un concreto convencional y otro con adición de vidrio reciclado molido. Se inició con el análisis de las propiedades físicas y químicas de los agregados pétreos y la elaboración de probetas de concreto y con adición de vidrio reciclado molido en el orden de 5%, 10%, 15%, 20%, 25% y 30% de reemplazo en peso del agregado fino, con la finalidad de obtener los tres porcentajes de adición más adecuados, según la cantidad de vidrio utilizado y la semejanza de la resistencia a la compresión obtenida con el concreto convencional. Seguidamente, se procedió a la rotura de las probetas de concreto mencionadas, obteniendo 15%, 20% y 25% como los porcentajes de adición de vidrio más adecuados. Posteriormente, se elaboró probetas de concreto convencional y modificado con 15%, 20% y 25% de vidrio reciclado molido, y se efectuó las pruebas de resistencia a la compresión a los 7, 14 y 28 días de curado. Al finalizar los ensayos de resistencia a la compresión, se concluyó que usando el 15% de adición de vidrio reciclado molido como reemplazo en peso del agregado fino se obtiene mayor resistencia a la compresión en comparación con el concreto convencional y los demás porcentajes de adición estudiados.

The following investigation had as main objective to analyze the compressive strength of F'c = 210 Kg / cm2 concrete with the addition of ground recycled glass, by partial replacement in weight of the fine aggregate in percentages of 15%, 20% and 25%, with the purpose of establishing a comparison between a conventional concrete and another with ground recycled glass and. The research began with the analysis of the physical and chemical properties of aggregates and the preparation of conventional concrete specimens, and with the participation in the order of 5%, 10%, 15%, 20%, 25% and 30% of replacement in weight of the fine aggregate, to obtain three percentages of the most suitable addition, according to the amount of glass and the similarity of the compressive strength with conventional concrete. Next, it proceeded to break the concrete specimens mentioned, obtaining 15%, 20% and 25% as the most suitable percentages of glass addition. Subsequently, the test specimens of conventional and modified concrete are made with 15%, 20% and 25% of ground recycled glass, and the compressive strength tests are carried out at 7, 14 and 28 days of curing. At the end of the compression strength tests, it was concluded that using 15% of the addition of ground recycled glass as weight replacement of the fine aggregate, greater compressive strength was obtained compared to the conventional concrete and the other percentages of addition studied.
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Nacional de San Martín. Facultad de Ingeniería Civil y Arquitectura
Grade or title: Ingeniero Civil
Juror: Alarcon Zamora, Jose Evergisto; Reategui Acedo, Ivan Gustavo; Chavez Cachay, Santiago
Register date: 3-Jul-2019; 3-Jul-2019



This item is licensed under a Creative Commons License Creative Commons