Look-up in Google Scholar
Title: Eficiencia teórica de cuatro tipos de cimentación superficial para una institución educativa
Advisor(s): Mosqueira Moreno, Miguel Ángel
OCDE field: https://purl.org/pe-repo/ocde/ford#2.01.01
Issue Date: 24-Apr-2018
Institution: Universidad Privada del Norte
Abstract: En la presente investigación se estudió el comportamiento de cuatro tipos de cimentaciones superficiales (zapata aislada, conectada, combinada y losa de cimentación), para una institución educativa de la localidad de Carbón Alto, distrito de Gregorio Pita – San Marcos – Cajamarca. El fin del estudio es determinar la eficiencia teórica de cuatro tipos de cimentación, para lo cual se analiza los asentamientos y las reacciones para determinar cuál de ellas se comporta mejor ante las cargas de servicio; también se compara los costos de cada una de ellas. En primer lugar, se realizó el diseño de las cimentaciones para conocer las dimensiones; para luego poder modelar en el software SAFE 2016 versión 16.0.1; a continuación, se realizó el metrado de cada una de las cimentaciones y se obtuvo el costo referencial, con los resultados obtenidos se hizo la comparación para conocer cuál es el tipo de cimentación más eficiente. Los resultados obtenidos nos determinaron que las zapatas conectadas son más eficientes, teniendo un comportamiento adecuado ante las cargas de servicio que se presentan en la institución educativa y teniendo un menor costo.

In the present investigation, the behavior of four types of superficial foundations (isolated, connected, combined footing and foundation slab) was studied for an educational institution in the town of Carbón Alto, district of Gregorio Pita - San Marcos - Cajamarca. The purpose of the study is to determine the theoretical efficiency of four types of foundations, for which the settlements and reactions are analyzed to determine which of them behaves better in the face of service loads; it also compares the costs of each of them. In the first place, the design of the foundations was made to know the dimensions; to then be able to model in the software SAFE 2016 version 16.0.1; Then, the metering of each of the foundations was performed and the referential cost was obtained, with the results obtained the comparison was made to know which is the most efficient type of foundation. The results obtained determined that the connected footings are more efficient, having an adequate behavior before the service loads that are presented in the educational institution and having a lower cost.
Note: Cajamarca
Discipline: Ingeniería Civil
Grade or title grantor: Universidad Privada del Norte. Facultad de Ingeniería
Grade or title: Ingeniero Civil
Juror: Aguilar Aliaga, Orlando; Quispe Rodríguez, Gerson; Alva Sarmiento, Anita Elizabet
Register date: 8-May-2018; 8-May-2018



This item is licensed under a Creative Commons License Creative Commons