La técnica de ultrasonido industrial es muy utilizada para detectar disconformidades internas en los materiales estructurales, como es importante determinar la posición exacta del defecto para posterior reparación, se requiere de bloques estándar de propiedades símiles al componente de ensayo que dispongan barrenos cuyas amplitudes permitan evaluar por comparación las generadas por defectos acorde a criterios de aceptabilidad establecidos en códigos de fabricación. El objetivo de la investigación fue fabricar un bloque para calibración en el sistema de prueba de ultrasonido mediante medidas acústicas conforme varia la frecuencia de oscilación. Los factores sónicos se registraron por la técnica pulso-eco y contacto directo, fueron realizadas 4 corridas en cada experimento y tres repeticiones con ondas acústicas longitudinales y corte con ángulo de refracción en acero de 70º, las frecuencias fueron 2.25 y 5.0 MHz. Los resultados indican que las medidas ultrasónicas varían con la frecuencia del transductor, con lo cual se recomienda utilizar para la inspección el mismo transductor utilizado para calibración. El bloque de referencia propuesto permitió calibrar en distancia y establecer curvas para referencia durante la evaluación de uniones por soldadura de acuerdo con los códigos ASME sección V y AWS D 1.1.
The industrial ultrasound technique is widely used to detect internal nonconformities in structural materials. As it is important to determine the exact position of the defect for subsequent repair, reference blocks with characteristics similar to the test element are required that have holes whose amplitudes allow evaluation. by comparison those generated by defects according to acceptability criteria established in manufacturing codes. The objective of the research was to manufacture a block for calibration in the ultrasound test system using acoustic measurements by varying the beam frequency. The acoustic factors were obtained by the pulse-echo technique and direct contact, 4 experimental runs with three repetitions were carried out to produce acoustic waves with a straight and transverse beam with a refraction angle in steel of 70º and frequencies of 2.25 and 5.0 MHz. The results indicate that ultrasonic measurements vary with the frequency of the transducer, which is why it is recommended to use the same transducer used for calibration for inspection. The proposed reference block allowed calibration in distance and establishment of reference curves for the inspection of welded joints according to the ASME section V and AWS D 1.1 codes.
application/pdf
spa
Universidad Nacional de Trujillo
info:eu-repo/semantics/openAccess
https://creativecommons.org/licenses/by-nc-nd/4.0/
Pruebas ultrasónicas
Frecuencia del palpador para pruebas ultrasónicas y su influencia en propiedades acústicas en un bloque estándar
info:eu-repo/semantics/bachelorThesis
Universidad Nacional de Trujillo Escuela de ingenieria Metalurgica
Ingenieria Metalurgica
Ingeniero Metalurgista
PE
https://purl.org/pe-repo/ocde/ford#2.00.00
http://purl.org/pe-repo/renati/level#tituloProfesional
18092322
0000-0001-8932-6119
73305877
78289744
713026
Rodriguez Aguilar, Wilfredo
Castillo Chung, Aldo Roger
Vera Alvarado, Jorge Wilfredo
http://purl.org/pe-repo/renati/type#tesis
Pública
info:eu-repo/semantics/publishedVersion



This item is licensed under a Creative Commons License Creative Commons