Look-up in Google Scholar
Full metadata record
Acevedo Obando, Grace Patricia
Bolivar Huaracha, Yadmani Ismael
Arismendi Diaz, Angel Pierre
2021-05-28T02:42:30Z
2021-05-28T02:42:30Z
2020
https://hdl.handle.net/20.500.12867/4134
El presente trabajo de investigación tiene como finalidad reducir los niveles de ruido que se generan en el área de molino de una fábrica de tuberías de PVC, a través de una propuesta de modelo de prototipo basado en el método de doble cerramiento hermético con materiales absorbentes. Para poder recolectar datos del nivel de ruido que se generan en el área de molino, se realizó un monitoreo preexperimental utilizando como referencia la RM. 375-2008-TR (norma básica de ergonómica y evaluación de riesgos ergonómicos) y NTP-ISO 9612:2010 (determinación de la exposición de ruido laboral), después de ello se obtuvo un nivel de presión sonora equivalente a 93.6 dB, el cual representa un valor que sobrepasa los límites máximos permisibles establecidos por la RM. 375 2008-TR. El modelo de prototipo lleva dentro de su estructura principal un elemento fundamental (material absorbente – lana de vidrio), el cual cumple la función de reducir el ruido a través de sus propiedades que posee para absorber toda la energía acústica que ingresa del exterior. Para su selección se tomó como referencia fichas técnicas de tres materiales con similitud en sus propiedades físicas, dada la comparación de estos, la lana de vidrio es el material que fue empleado en el modelo de prototipo, así mismo se complementó su estructura con otros dos materiales que ayudaron a la resistencia contra la humedad (placa RH) y resistencia contra el fuego o altas temperaturas (placa RF). Una vez que se definió el material absorbente, se trabajó en el diseño y ensamblaje del modelo de prototipo basado en el método de doble cerramiento hermético conformado por dos cajas reductoras de ruido. Después de haber ensamblado el modelo de prototipo, se hizo un monitoreo post experimental con el objetivo de comprobar la eficiencia y la cantidad de decibelios que reduce este: la primera evaluación fue realizada con la primera caja reductora de ruido, la segunda con la primera y la segunda caja reductora puestas en simultáneo y por último se hizo una evaluación solo con la segunda caja; estas mediciones fueron realizadas a 1m. y 2m. de distancia cada muestra arrojando valores positivos: CR.1: 69.0 dB y 65.9 dB; CR 1 y 2: 63.4 dB y 60.4 dB y por último con la CR. 2: 70.4 dB y 68.4 dB, siendo estos valores los cuales no superan los límites máximos permisibles. (es_PE)
The purpose of this research work is to reduce the noise levels that are generated in the mill area of a PVC pipe factory, through a proposal for a prototype model based on the method of double hermetic closure with absorbent materials. In order to collect data on the noise level generated in the mill area, a pre-experimental monitoring was carried out using as a reference. RM. 375-2008-TR (Basic standard for ergonomics and evaluation of disergonomic risks) and NTP-ISO 9612: 2010 (Determination of occupational noise exposure), after which a sound pressure level equivalent to 93.6 dB was obtained, which represents a value that exceeds the maximum permissible limits established by the RM. 375 2008-TR. The prototype model has within its main structure a fundamental element (absorbent material - glass wool), which fulfills the function of reducing noise through its properties that it has to absorb all the acoustic energy that enters from the outside. For its selection, technical sheets of three materials with similarity in their physical properties were taken as a reference, given the comparison of these, glass wool is the material that was used in the prototype model, likewise its structure was supplemented with two others materials that aided resistance against humidity (RH plate) and resistance against fire or high temperatures (RF plate). Once the absorbent material was defined, work was done on the design and assembly of the prototype model based on the double hermetic closure method consisting of two noise reducing boxes. After having assembled the prototype model, a post-experimental monitoring was carried out in order to check the efficiency and the amount of decibels that it reduces: the first evaluation was carried out with the first noise reduction box, the second with the first and the second gearbox put in simultaneous and finally an evaluation was made only with the second gearbox, these measurements were made at 1m. and 2m. distance each sample yielding positive values: CR.1: 69.0 dB and 65.9 dB; CR 1 and 2: 63.4 dB and 60.4 dB and finally with the CR. 2: 70.4 dB and 68.4 dB, these values being which do not exceed the maximum permissible limits. (es_PE)
application/pdf (es_PE)
spa (es_PE)
Universidad Tecnológica del Perú (es_PE)
info:eu-repo/semantics/openAccess (es_PE)
http://creativecommons.org/licenses/by-nc-sa/4.0/ (es_PE)
Repositorio Institucional - UTP (es_PE)
Universidad Tecnológica del Perú (es_PE)
Reducción de ruido (es_PE)
Ruido ocupacional (es_PE)
Cerramiento hermético (es_PE)
Procesos industriales (es_PE)
Propuesta de un modelo de prototipo basado en el método de doble cerramiento hermético con materiales absorbentes para reducir el ruido a niveles permisibles en el área de molino de una fábrica de tuberías de PVC-Arequipa 2019 (es_PE)
info:eu-repo/semantics/bachelorThesis (es_PE)
Universidad Tecnológica del Perú. Facultad de Ingeniería (es_PE)
Ingeniería de Seguridad Industrial y Minera (es_PE)
Ingeniero de Seguridad Industrial y Minera (es_PE)
PE (es_PE)
https://purl.org/pe-repo/ocde/ford#2.11.04 (es_PE)
http://purl.org/pe-repo/renati/level#tituloProfesional (es_PE)
42673518
https://orcid.org/0000-0003-1113-9369 (es_PE)
47027232
60467929
724066 (es_PE)
Ardiles Flores, Carlos Christiand
Herrera Torreblanca, Ximena Johana
Cabrera Choccata, Daysy Yanina
http://purl.org/pe-repo/renati/type#tesis (es_PE)
Privada societaria
info:eu-repo/semantics/publishedVersion (es_PE)



This item is licensed under a Creative Commons License Creative Commons