Look-up in Google Scholar
Title: Evaluación de reservorios elevados tipo marco con fines de normatividad
Advisor(s): Arrieta Freyre, Javier Eduardo
OCDE field: http://purl.org/pe-repo/ocde/ford#2.01.03
Issue Date: 2021
Institution: Universidad Nacional de Ingeniería
Abstract: Desde 1970 el Perú cuenta con normatividad sismorresistente para edificaciones, pero hasta la fecha no ha implementado una norma específica para estructuras especiales como los reservorios elevados de almacenamiento de agua con soporte tipo marco de concreto armado. Los reservorios elevados de almacenamiento de agua son estructuras de vital importancia, ya que deben garantizar su servicio antes, durante y después de la ocurrencia de un evento sísmico severo y poder satisfacer todas las demandas de agua de la población. Hasta la actualidad en el Perú, se han construido y se siguen construyendo reservorios elevados de almacenamiento de agua con soporte tipo marco de concreto armado, sin embargo, no se cuenta con una normatividad específica para este tipo de estructuras, hecho que me motivo a establecer como objetivo la implementación de un manual relacionado a la determinación de la fuerza sísmica y el desplazamiento lateral de este tipo de estructuras. El procedimiento para alcanzar el objetivo del presente trabajo, se basó en el conocimiento del comportamiento hidrodinámico del agua, el empleo de modelos mecánicos en el estudio de la respuesta de los reservorios de almacenamiento de agua frente a solicitaciones sísmicas, el empleo de la normatividad sísmica nacional e internacional aplicada a reservorios elevados y su aplicación en reservorios elevados con soporte tipo marco de concreto armado. Finalmente empleando la NTE 030-18, NTE 060-09, ACI 350.3-06 y ITTK-GDSMA 2007, pudimos obtener la fuerza sísmica, el desplazamiento lateral y el desplazamiento lateral relativo en 02 reservorios elevados existentes con soporte tipo marco de concreto armado, el primero de 36m3 de capacidad ubicado en la ciudad de Ica y el segundo de 200m3 de capacidad ubicado en la ciudad de Tingo María.

Since 1970, Peru has earthquake resistant regulations for buildings, but to date it has not implemented a specific standard for special structures such as elevated water storage reservoirs with reinforced concrete frame-type support. Elevated water storage reservoirs are structures of vital importance, since they must guarantee their service before, during and after the occurrence of a sever seismic event and be able to satisfy all the water demands of the population. Until now, in Peru, elevated water storage reservoirs with reinforced concrete frame-type support have been and continue to be built, however, there are no specific regulations for this type of structures, a fact that motivated me to establish as an objective the implementation of a manual related to the determination of the seismic force and the lateral displacement of this type of structures. The procedure to achieve the objective of this work was based on the knowledge of the hydrodynamic behavior of water, the use of mechanical models in the study of the response of water storage reservoirs to seismic solicitations, the use of seismic regulations. national and international applied to elevated reservoirs and its application in elevated reservoirs with reinforced concrete frame-type support. Finally, using the NTE 030-18, NTE 060-09, ACI 350.3-06 and ITTK-GDSMA 2007, we were able to obtain the seismic force, lateral displacement and relative lateral displacement in 02 existing elevated reservoirs with reinforced concrete frame type support, the first with 36m3 capacity located in the city of Ica and the second with 200m3 capacity located in the city of Tingo María.
Discipline: Maestría en Tecnología de la Construcción
Grade or title grantor: Universidad Nacional de Ingeniería. Facultad de Ingeniería Civil. Unidad de Posgrado
Grade or title: Maestro en Tecnología de la Construcción
Juror: Jiménez Yabar, Heddy Marcela; Durán Querol, Rodolfo Martín; Quevedo De la Cruz, Isaías Jesús; Gutiérrez Lázares, José Wilfredo
Register date: 20-Sep-2022



This item is licensed under a Creative Commons License Creative Commons