Quiñones, S., (2021). Análisis y diseño de una torre de telecomunicaciones de 90 m de altura [Trabajo de suficiencia profesional, Universidad Nacional de Ingeniería]. http://hdl.handle.net/20.500.14076/22205
Quiñones, S., Análisis y diseño de una torre de telecomunicaciones de 90 m de altura [Trabajo de suficiencia profesional]. PE: Universidad Nacional de Ingeniería; 2021. http://hdl.handle.net/20.500.14076/22205
@misc{renati/711736,
title = "Análisis y diseño de una torre de telecomunicaciones de 90 m de altura",
author = "Quiñones Luna, Santa Bertila",
publisher = "Universidad Nacional de Ingeniería",
year = "2021"
}
Full metadata record
Zavala Toledo, Carlos Alberto
Quiñones Luna, Santa Bertila
Quiñones Luna, Santa Bertila
2022-06-06T21:11:28Z
2022-06-06T21:11:28Z
2021
http://hdl.handle.net/20.500.14076/22205
Se presenta el análisis y diseño de una torre de telecomunicaciones de 90m de altura desplantada en el departamento de Madre de Dios bajo las recomendaciones de la normativa TIA 222 G. En el Perú no existe normativa para este tipo de estructuras, son las empresas propietarias de las torres quienes solicitan el diseño empleando una de las siguientes normativas: TIA 222 F o TIA 222 G. La primera de ellas sólo considera las demandas de viento y el diseño por esfuerzos permisibles (ASD, por sus siglas en inglés); mientras que, en la segunda normativa, a parte de las fuerzas de viento, se deben incluir las fuerzas de sismo como parte del análisis y el diseño es por factores de carga y resistencia (LRFD, por sus siglas en inglés). Se comparan los procedimientos que desarrolla cada una de las normas F y G en el cálculo de las fuerzas de viento y los cálculos necesarios para obtener las demandas sísmicas. Para el caso de la torre estudiada, por la ubicación y la configuración estructural, es el viento quien gobierna el diseño, pues las fuerzas sísmicas son menores que la mitad de aquellas debido al viento. (es)
Analysis and design of a communication tower of 90m in height on Madre de Dios department were developed under TIA 222 G code. In Peru, there is no code for this kind of structures so the tower’s owners are who establish the use of TIA 222 F or TIA 222 G. The first code takes into account only wind actions, and its design is based on allowable stress design (ASD), while code TIA 222 G some differences for wind forces calculations and include seismic actions; load and resistance factor design (LRFD) is used for steel design. Also, a comparison between both codes of procedure for the calculation of wind forces is shown. For tower development in this thesis according to location and structural configuration, seismic forces were put aside because these were less than half of the wind ones. (en)
Trabajo de suficiencia profesional (es)
application/pdf (es)
spa (es)
Universidad Nacional de Ingeniería (es)
info:eu-repo/semantics/restrictedAccess (es)
http://creativecommons.org/licenses/by-nc-nd/4.0/ (es)
Universidad Nacional de Ingeniería (es)
Repositorio Institucional - UNI (es)
Torre de telecomunicaciones (es)
Normativa TIA 222 F (es)
Normativa TIA 222 G (es)
Análisis y diseño de una torre de telecomunicaciones de 90 m de altura (es)
info:eu-repo/semantics/bachelorThesis (es)
Universidad Nacional de Ingeniería. Facultad de Ingeniería Civil (es)
Ingeniería Civil (es)
Título Profesional (es)
Ingeniero Civil (es)
PE (es)
http://purl.org/pe-repo/ocde/ford#2.01.01 (es)
Ingeniería (es)
http://purl.org/pe-repo/renati/nivel#tituloProfesional (es)
06302877
https://orcid.org/0000-0001-9472-2036 (es)
09972285
732016
Salinas Basualdo, Rafael Rolando
Reyna Salazar, Roy Ericksen
http://purl.org/pe-repo/renati/type#trabajoDeSuficienciaProfesional (es)
Pública
This item is licensed under a Creative Commons License